FabDigitFabDigit

Copper Alloy C69430-H02 vs C69430-H04

Copper Alloy · C69430 temper comparison

C69430-H02 and C69430-H04 are two conditions of the same copper alloy grade, C69430: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C69430-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 345 MPa (50 ksi) for C69430-H02, about 20% more; tensile strength follows at 690 MPa (100 ksi) vs 620 MPa (89.9 ksi). In exchange, C69430-H02 is the more ductile: elongation 22% versus 18% for C69430-H04, and C69430-H04 is harder (190 HB vs 170 HB). C69430-H02 runs hotter in service (180°C vs 160°C continuous).

C69430-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C69430-H04Choose it when strength drives the design.

C69430-H02 vs C69430-H04: properties

C69430-H02C69430-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

345 MPa50 ksi
415 MPa60.2 ksi

Elongation at Break

22%
18%

Reduction in Area

38%
30%

Shear Strength

390 MPa56.6 ksi
425 MPa61.6 ksi

Fatigue Strength (Endurance Limit)

225 MPa32.6 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

35 J25.8 ft·lbf
28 J20.7 ft·lbf

Hardness, Brinell

170 HB
190 HB

Hardness, Rockwell B

88 HRB
92 HRB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 820°C1,508 °F · Liquidus Temperature 916°C1,681 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
160°C320 °F

Same in both: Thermal Conductivity 27 W/m·K15.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.6 % IACS
6.5 % IACS

Electrical Resistivity

2.61×10⁻⁷ Ω·m10.3 µΩ·in
2.65×10⁻⁷ Ω·m10.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

69 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

95%
100%

Weldability

72 / 100
70 / 100

Formability (cold)

30 / 100
22 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC69430

C69430-H02 vs C69430-H04 — frequently asked

Is C69430-H04 stronger than C69430-H02?

Yes. C69430-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 345 MPa (50 ksi) for C69430-H02 — about 20% more. Tensile strength is 690 MPa (100 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, H02 or H04?

M30 is the default C69430 condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C69430-H02 over C69430-H04?

Pick C69430-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C69430-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C69430-H02 and C69430-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.