C67500-H04 and C67500-M10 are two conditions of the same copper alloy grade, C67500: H04 (full hard) versus M10 (as hot forged and air cooled). The chemistry is identical, so every difference below comes from the condition. C67500-H04 is the stronger of the two: yield strength 414 MPa (60 ksi) against 207 MPa (30 ksi) for C67500-M10, about 100% more; tensile strength follows at 579 MPa (84 ksi) vs 483 MPa (70.1 ksi). In exchange, C67500-M10 is the more ductile: elongation 30% versus 15% for C67500-H04, and C67500-H04 is harder (180 HB vs 140 HB). C67500-M10 runs hotter in service (200°C vs 180°C continuous).

C67500-H04Choose it when strength drives the design.

C67500-M10Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C67500-H04 vs C67500-M10: properties

C67500-H04C67500-M10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

579 MPa84 ksi
483 MPa70.1 ksi

Yield Strength (0.2% offset)

414 MPa60 ksi
207 MPa30 ksi

Elongation at Break

15%
30%

Shear Strength

350 MPa50.8 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
170 MPa24.7 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

180 HB
140 HB

Hardness, Rockwell B

88 HRB
76 HRB

Hardness, Vickers

192 HV
170 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.32 · Reduction in Area 40%

Physical

Density and transition temperatures.

Same in both: Density 8.36 g/cm³0.3 lb/in³ · Melting Point (Solidus) 865°C1,589 °F · Liquidus Temperature 888°C1,630 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Thermal Conductivity 100 W/m·K57.8 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

23 % IACS
24 % IACS

Same in both: Electrical Resistivity 7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.29 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Formability (cold)

25 / 100
45 / 100

Same in both: Weldability 55 / 100 · Castability 65 / 100 · Brazeability / Solderability 78 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 50 MJ/kg21,496 BTU/lb · Embodied Carbon (primary production) 3.4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 55%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC67500

C67500-H04 vs C67500-M10 — frequently asked

Is C67500-H04 stronger than C67500-M10?

Yes. C67500-H04 has a typical yield strength of 414 MPa (60 ksi) against 207 MPa (30 ksi) for C67500-M10 — about 100% more. Tensile strength is 579 MPa (84 ksi) vs 483 MPa (70.1 ksi).

Which condition does FabDigit quote by default, H04 or M10?

H02 is the default C67500 condition in the FabDigit quote flow (neither H04 nor M10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C67500-H04 or C67500-M10?

C67500-H04. Its machinability rates fair (35/100) against poor (30/100) for C67500-M10.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C67500-H04 and C67500-M10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.