FabDigitFabDigit

Copper Alloy C67400-H02 vs C67400-O60

Copper Alloy · C67400 temper comparison

C67400-H02 and C67400-O60 are two conditions of the same copper alloy grade, C67400: H02 (half hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C67400-H02 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for C67400-O60, about 73% more; tensile strength follows at 725 MPa (105 ksi) vs 585 MPa (84.8 ksi). In exchange, C67400-O60 is the more ductile: elongation 30% versus 15% for C67400-H02, and C67400-H02 is harder (200 HB vs 150 HB).

C67400-H02Choose it when strength drives the design.

C67400-O60Choose it when the part is bent, formed or impact-loaded.

C67400-H02 vs C67400-O60: properties

C67400-H02C67400-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
260 MPa37.7 ksi

Elongation at Break

15%
30%

Reduction in Area

30%
50%

Shear Strength

435 MPa63.1 ksi
360 MPa52.2 ksi

Fatigue Strength (Endurance Limit)

205 MPa29.7 ksi
170 MPa24.7 ksi

Hardness, Brinell

200 HB
150 HB

Hardness, Rockwell B

93 HRB
78 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 25 J18.4 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.36 g/cm³0.3 lb/in³ · Melting Point (Solidus) 862°C1,584 °F · Liquidus Temperature 880°C1,616 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 40 W/m·K23.1 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 8 % IACS · Electrical Resistivity 2.15×10⁻⁷ Ω·m8.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
25 / 100

Formability (cold)

25 / 100
55 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 75% · Weldability 35 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC67400

C67400-H02 vs C67400-O60 — frequently asked

Is C67400-H02 stronger than C67400-O60?

Yes. C67400-H02 has a typical yield strength of 450 MPa (65.3 ksi) against 260 MPa (37.7 ksi) for C67400-O60 — about 73% more. Tensile strength is 725 MPa (105 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, H02 or O60?

M30 is the default C67400 condition in the FabDigit quote flow (neither H02 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C67400-H02 or C67400-O60?

C67400-H02, by a small margin. Both rate poor for machinability — 32/100 against 25/100 for C67400-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C67400-H02 and C67400-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.