C67300-H02 and C67300-M11 are two conditions of the same copper alloy grade, C67300: H02 (half hard) versus M11 (as forged and quenched). The chemistry is identical, so every difference below comes from the condition. C67300-H02 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 290 MPa (42.1 ksi) for C67300-M11, about 43% more; tensile strength follows at 640 MPa (92.8 ksi) vs 570 MPa (82.7 ksi). In exchange, C67300-M11 is the more ductile: elongation 25% versus 18% for C67300-H02, and C67300-H02 is harder (170 HB vs 140 HB). C67300-M11 runs hotter in service (200°C vs 180°C continuous).

C67300-H02Choose it when strength drives the design.

C67300-M11Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C67300-H02 vs C67300-M11: properties

C67300-H02C67300-M11

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

640 MPa92.8 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
290 MPa42.1 ksi

Elongation at Break

18%
25%

Reduction in Area

30%
38%

Shear Strength

395 MPa57.3 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

215 MPa31.2 ksi
195 MPa28.3 ksi

Hardness, Brinell

170 HB
140 HB

Hardness, Rockwell B

87 HRB
77 HRB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.19 g/cm³0.3 lb/in³ · Melting Point (Solidus) 855°C1,571 °F · Liquidus Temperature 880°C1,616 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Thermal Conductivity 60 W/m·K34.7 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 12 % IACS · Electrical Resistivity 1.44×10⁻⁷ Ω·m5.67 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
75 / 100

Machinability Rating (AISI 1212 = 100 %)

250%
240%

Weldability

18 / 100
20 / 100

Formability (cold)

20 / 100
28 / 100

Same in both: Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.3 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC67300

C67300-H02 vs C67300-M11 — frequently asked

Is C67300-H02 stronger than C67300-M11?

Yes. C67300-H02 has a typical yield strength of 415 MPa (60.2 ksi) against 290 MPa (42.1 ksi) for C67300-M11 — about 43% more. Tensile strength is 640 MPa (92.8 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, H02 or M11?

M30 is the default C67300 condition in the FabDigit quote flow (neither H02 nor M11). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C67300-H02 over C67300-M11?

Pick C67300-H02 when strength drives the design. Pick C67300-M11 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C67300-H02 and C67300-M11 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.