C66200-H01 and C66200-H06 are two conditions of the same copper alloy grade, C66200: H01 (quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C66200-H06 is the stronger of the two: yield strength 545 MPa (79 ksi) against 290 MPa (42.1 ksi) for C66200-H01, about 88% more; tensile strength follows at 615 MPa (89.2 ksi) vs 420 MPa (60.9 ksi). In exchange, C66200-H01 is the more ductile: elongation 25% versus 4% for C66200-H06, and C66200-H06 is harder (183 HB vs 120 HB). C66200-H01 runs hotter in service (200°C vs 160°C continuous).

C66200-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C66200-H06Choose it when strength drives the design.

C66200-H01 vs C66200-H06: properties

C66200-H01C66200-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

420 MPa60.9 ksi
615 MPa89.2 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
545 MPa79 ksi

Elongation at Break

25%
4%

Shear Strength

270 MPa39.2 ksi
370 MPa53.7 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
185 MPa26.8 ksi

Hardness, Brinell

120 HB
183 HB

Hardness, Rockwell B

68 HRB
90 HRB

Hardness, Vickers

128 HV
197 HV

Same in both: Elastic (Young's) Modulus 115 GPa16.7 Msi · Shear Modulus 43 GPa6.2 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.53 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 940°C1,724 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
160°C320 °F

Same in both: Thermal Conductivity 60 W/m·K34.7 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.5 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 14 % IACS · Electrical Resistivity 1.23×10⁻⁷ Ω·m4.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
33%

Weldability

55 / 100
50 / 100

Formability (cold)

70 / 100
25 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC66200

C66200-H01 vs C66200-H06 — frequently asked

Is C66200-H06 stronger than C66200-H01?

Yes. C66200-H06 has a typical yield strength of 545 MPa (79 ksi) against 290 MPa (42.1 ksi) for C66200-H01 — about 88% more. Tensile strength is 615 MPa (89.2 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, H01 or H06?

HR02 is the default C66200 condition in the FabDigit quote flow (neither H01 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C66200-H01 or C66200-H06?

C66200-H06. Its machinability rates fair (35/100) against poor (30/100) for C66200-H01; for welding the order is C66200-H01 first (good, 55/100) then C66200-H06 (fair, 50/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C66200-H01 and C66200-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.