FabDigitFabDigit

Copper Alloy C64700-TB00 vs C64700-TF00

Copper Alloy · C64700 temper comparison

C64700-TB00 and C64700-TF00 are two conditions of the same copper alloy grade, C64700: TB00 (solution heat treated) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C64700-TF00 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 140 MPa (20.3 ksi) for C64700-TB00, about 196% more; tensile strength follows at 550 MPa (79.8 ksi) vs 340 MPa (49.3 ksi). In exchange, C64700-TB00 is the more ductile: elongation 45% versus 18% for C64700-TF00, and C64700-TF00 is harder (165 HB vs 85 HB). C64700-TF00 runs hotter in service (200°C vs 150°C continuous) and C64700-TF00 conducts heat better (155 W/m·K vs 110 W/m·K). On the shop floor, C64700-TF00 machines more easily (fair vs poor).

C64700-TB00Choose it when the part is bent, formed or impact-loaded.

C64700-TF00Choose it when strength drives the design, or when the part sees heat.

C64700-TB00 vs C64700-TF00: properties

C64700-TB00C64700-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

130 GPa18.9 Msi
132 GPa19.1 Msi

Tensile Strength (Ultimate)

340 MPa49.3 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
415 MPa60.2 ksi

Elongation at Break

45%
18%

Reduction in Area

65%
45%

Shear Strength

215 MPa31.2 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
220 MPa31.9 ksi

Hardness, Brinell

85 HB
165 HB

Hardness, Rockwell B

48 HRB
88 HRB

Hardness, Vickers

90 HV
175 HV

Same in both: Shear Modulus 49 GPa7.1 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,090°C1,994 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
38 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
4.5×10⁻⁸ Ω·m1.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
30%

Weldability

75 / 100
70 / 100

Formability (cold)

90 / 100
45 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 75 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC64700

C64700-TB00 vs C64700-TF00 — frequently asked

Is C64700-TF00 stronger than C64700-TB00?

Yes. C64700-TF00 has a typical yield strength of 415 MPa (60.2 ksi) against 140 MPa (20.3 ksi) for C64700-TB00 — about 196% more. Tensile strength is 550 MPa (79.8 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, TB00 or TF00?

TF00 is the default C64700 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C64700-TB00 or C64700-TF00?

C64700-TF00. Its machinability rates fair (40/100) against poor (28/100) for C64700-TB00; for welding the order is C64700-TB00 first (very good, 75/100) then C64700-TF00 (very good, 70/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C64700-TB00 and C64700-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.