FabDigitFabDigit

Copper Alloy C63800-H02 vs C63800-O61

Copper Alloy · C63800 temper comparison

C63800-H02 and C63800-O61 are two conditions of the same copper alloy grade, C63800: H02 (half hard) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C63800-H02 is the stronger of the two: yield strength 650 MPa (94.3 ksi) against 290 MPa (42.1 ksi) for C63800-O61, about 124% more; tensile strength follows at 725 MPa (105 ksi) vs 570 MPa (82.7 ksi). In exchange, C63800-O61 is the more ductile: elongation 35% versus 10% for C63800-H02, and C63800-H02 is harder (225 HV vs 170 HV). C63800-O61 runs hotter in service (300°C vs 220°C continuous).

C63800-H02Choose it when strength drives the design.

C63800-O61Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C63800-H02 vs C63800-O61: properties

C63800-H02C63800-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

650 MPa94.3 ksi
290 MPa42.1 ksi

Elongation at Break

10%
35%

Shear Strength

430 MPa62.4 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

285 MPa41.3 ksi
240 MPa34.8 ksi

Hardness, Rockwell B

95 HRB
86 HRB

Hardness, Vickers

225 HV
170 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.32 · Hardness, Brinell 255 HB · Hardness, Rockwell C 25 HRC

Physical

Density and transition temperatures.

Same in both: Density 7.69 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,060°C1,940 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

220°C428 °F
300°C572 °F

Same in both: Thermal Conductivity 44.6 W/m·K25.8 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.9 µm/m·K9.4 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.72×10⁻⁷ Ω·m6.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 74 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

46 / 100
72 / 100

Same in both: Machinability 32 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Castability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC63800

C63800-H02 vs C63800-O61 — frequently asked

Is C63800-H02 stronger than C63800-O61?

Yes. C63800-H02 has a typical yield strength of 650 MPa (94.3 ksi) against 290 MPa (42.1 ksi) for C63800-O61 — about 124% more. Tensile strength is 725 MPa (105 ksi) vs 570 MPa (82.7 ksi).

Which condition does FabDigit quote by default, H02 or O61?

H08 is the default C63800 condition in the FabDigit quote flow (neither H02 nor O61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C63800-H02 over C63800-O61?

Pick C63800-H02 when strength drives the design. Pick C63800-O61 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C63800-H02 and C63800-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.