FabDigitFabDigit

Copper Alloy C63800-H02 vs C63800-H08

Copper Alloy · C63800 temper comparison

C63800-H02 and C63800-H08 are two conditions of the same copper alloy grade, C63800: H02 (half hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C63800-H08 is the stronger of the two: yield strength 855 MPa (124 ksi) against 650 MPa (94.3 ksi) for C63800-H02, about 32% more; tensile strength follows at 895 MPa (130 ksi) vs 725 MPa (105 ksi). In exchange, C63800-H02 is the more ductile: elongation 10% versus 4% for C63800-H08, and C63800-H08 is harder (270 HV vs 225 HV). C63800-H02 runs hotter in service (220°C vs 200°C continuous).

C63800-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C63800-H08Choose it when strength drives the design.

C63800-H02 vs C63800-H08: properties

C63800-H02C63800-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

725 MPa105 ksi
895 MPa130 ksi

Yield Strength (0.2% offset)

650 MPa94.3 ksi
855 MPa124 ksi

Elongation at Break

10%
4%

Shear Strength

430 MPa62.4 ksi
520 MPa75.4 ksi

Fatigue Strength (Endurance Limit)

285 MPa41.3 ksi
310 MPa45 ksi

Hardness, Rockwell B

95 HRB
99 HRB

Hardness, Vickers

225 HV
270 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.32 · Hardness, Brinell 255 HB · Hardness, Rockwell C 25 HRC

Physical

Density and transition temperatures.

Same in both: Density 7.69 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,060°C1,940 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

220°C428 °F
200°C392 °F

Same in both: Thermal Conductivity 44.6 W/m·K25.8 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.9 µm/m·K9.4 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 10 % IACS · Electrical Resistivity 1.72×10⁻⁷ Ω·m6.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 74 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

46 / 100
20 / 100

Same in both: Machinability 32 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Castability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC63800

C63800-H02 vs C63800-H08 — frequently asked

Is C63800-H08 stronger than C63800-H02?

Yes. C63800-H08 has a typical yield strength of 855 MPa (124 ksi) against 650 MPa (94.3 ksi) for C63800-H02 — about 32% more. Tensile strength is 895 MPa (130 ksi) vs 725 MPa (105 ksi).

Which condition does FabDigit quote by default, H02 or H08?

H08 is the default C63800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C63800-H02 over C63800-H08?

Pick C63800-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C63800-H08 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C63800-H02 and C63800-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.