FabDigitFabDigit

Copper Alloy C61600-H01 vs C61600-O61

Copper Alloy · C61600 temper comparison

C61600-H01 and C61600-O61 are two conditions of the same copper alloy grade, C61600: H01 (quarter hard) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C61600-H01 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 170 MPa (24.7 ksi) for C61600-O61, about 41% more; tensile strength follows at 430 MPa (62.4 ksi) vs 400 MPa (58 ksi). In exchange, C61600-O61 is the more ductile: elongation 55% versus 40% for C61600-H01, and C61600-H01 is harder (112 HB vs 80 HB). C61600-O61 runs hotter in service (250°C vs 230°C continuous).

C61600-H01Choose it when strength drives the design.

C61600-O61Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C61600-H01 vs C61600-O61: properties

C61600-H01C61600-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
170 MPa24.7 ksi

Elongation at Break

40%
55%

Shear Strength

275 MPa39.9 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
140 MPa20.3 ksi

Hardness, Brinell

112 HB
80 HB

Hardness, Rockwell B

63 HRB
55 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.2 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,040°C1,904 °F · Liquidus Temperature 1,060°C1,940 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

230°C446 °F
250°C482 °F

Same in both: Thermal Conductivity 88 W/m·K50.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 18 % IACS · Electrical Resistivity 9.6×10⁻⁸ Ω·m3.78 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

75 / 100
85 / 100

Same in both: Machinability 35 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 75 / 100 · Castability 40 / 100 · Brazeability / Solderability 30 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC61600

C61600-H01 vs C61600-O61 — frequently asked

Is C61600-H01 stronger than C61600-O61?

Yes. C61600-H01 has a typical yield strength of 240 MPa (34.8 ksi) against 170 MPa (24.7 ksi) for C61600-O61 — about 41% more. Tensile strength is 430 MPa (62.4 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H01 or O61?

O61 is the default C61600 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C61600-H01 over C61600-O61?

Pick C61600-H01 when strength drives the design. Pick C61600-O61 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C61600-H01 and C61600-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.