C61400-M20 and C61400-M30 are two conditions of the same copper alloy grade, C61400: M20 (as hot rolled) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C61400-M30 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 230 MPa (33.4 ksi) for C61400-M20, about 9% more. In exchange, C61400-M20 is the more ductile: elongation 45% versus 38% for C61400-M30.

C61400-M20Choose it when the part is bent, formed or impact-loaded.

C61400-M30Choose it when strength drives the design.

C61400-M20 vs C61400-M30: properties

C61400-M20C61400-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

525 MPa76.1 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
250 MPa36.3 ksi

Elongation at Break

45%
38%

Reduction in Area

50%
45%

Shear Strength

340 MPa49.3 ksi
350 MPa50.8 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
195 MPa28.3 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

140 HB
145 HB

Hardness, Rockwell B

80 HRB
82 HRB

Hardness, Vickers

150 HV
155 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.89 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,040°C1,904 °F · Liquidus Temperature 1,045°C1,913 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 66.6 W/m·K38.5 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 14 % IACS · Electrical Resistivity 1.23×10⁻⁷ Ω·m4.84 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

55 / 100
50 / 100

Same in both: Machinability 28 / 100 · Machinability Rating (AISI 1212 = 100 %) 50% · Weldability 70 / 100 · Castability 55 / 100 · Brazeability / Solderability 30 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC61400

C61400-M20 vs C61400-M30 — frequently asked

Is C61400-M30 stronger than C61400-M20?

Yes. C61400-M30 has a typical yield strength of 250 MPa (36.3 ksi) against 230 MPa (33.4 ksi) for C61400-M20 — about 9% more. Tensile strength is 550 MPa (79.8 ksi) vs 525 MPa (76.1 ksi).

Which condition does FabDigit quote by default, M20 or M30?

M20 is the default C61400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C61400-M20 over C61400-M30?

Pick C61400-M20 when the part is bent, formed or impact-loaded. Pick C61400-M30 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C61400-M20 and C61400-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.