C61300-AW and C61300-O60 are two conditions of the same copper alloy grade, C61300: AW (as-welded deposit) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C61300-AW is the stronger of the two: yield strength 260 MPa (37.7 ksi) against 205 MPa (29.7 ksi) for C61300-O60, about 27% more. In exchange, C61300-O60 is the more ductile: elongation 45% versus 30% for C61300-AW, and C61300-AW is harder (145 HB vs 128 HB).

C61300-AWChoose it when strength drives the design.

C61300-O60Choose it when the part is bent, formed or impact-loaded.

C61300-AW vs C61300-O60: properties

C61300-AWC61300-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

540 MPa78.3 ksi
515 MPa74.7 ksi

Yield Strength (0.2% offset)

260 MPa37.7 ksi
205 MPa29.7 ksi

Elongation at Break

30%
45%

Reduction in Area

32%
48%

Shear Strength

335 MPa48.6 ksi
325 MPa47.1 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

145 HB
128 HB

Hardness, Rockwell B

78 HRB
73 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.32 · Fatigue Strength (Endurance Limit) 195 MPa28.3 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.89 g/cm³0.29 lb/in³ · Melting Point (Solidus) 1,038°C1,900 °F · Liquidus Temperature 1,046°C1,915 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

60 W/m·K34.7 BTU/hr·ft·°F
62 W/m·K35.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10.5 % IACS
10.9 % IACS

Electrical Resistivity

1.64×10⁻⁷ Ω·m6.46 µΩ·in
1.58×10⁻⁷ Ω·m6.22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
75 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
25%

Formability (cold)

45 / 100
72 / 100

Same in both: Weldability 78 / 100 · Castability 55 / 100 · Brazeability / Solderability 32 / 100 · Polishability 72 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC61300

C61300-AW vs C61300-O60 — frequently asked

Is C61300-AW stronger than C61300-O60?

Yes. C61300-AW has a typical yield strength of 260 MPa (37.7 ksi) against 205 MPa (29.7 ksi) for C61300-O60 — about 27% more. Tensile strength is 540 MPa (78.3 ksi) vs 515 MPa (74.7 ksi).

Which condition does FabDigit quote by default, AW or O60?

M20 is the default C61300 condition in the FabDigit quote flow (neither AW nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C61300-AW over C61300-O60?

Pick C61300-AW when strength drives the design. Pick C61300-O60 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C61300-AW and C61300-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.