Copper Alloy C60800-O60 vs C60800-O61

Copper Alloy · C60800 temper comparison

C60800-O60 and C60800-O61 are two conditions of the same copper alloy grade, C60800: O60 (soft annealed) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C60800-O61 is the stronger of the two: yield strength 186 MPa (27 ksi) against 165 MPa (23.9 ksi) for C60800-O60, about 13% more. C60800-O61 is harder — 100 HB against 88 HB for C60800-O60 — which matters for wear surfaces and threads.

C60800-O61Choose it when strength drives the design, or when surface hardness matters.

C60800-O60 vs C60800-O61: properties

C60800-O60C60800-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
186 MPa27 ksi

Elongation at Break

60%
55%

Reduction in Area

70%
65%

Shear Strength

240 MPa34.8 ksi
255 MPa37 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
150 MPa21.8 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

88 HB
100 HB

Hardness, Rockwell B

48 HRB
55 HRB

Hardness, Vickers

92 HV
105 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.17 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,035°C1,895 °F · Liquidus Temperature 1,055°C1,931 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 82 W/m·K47.4 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 17 % IACS · Electrical Resistivity 1.01×10⁻⁷ Ω·m3.98 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V · Corrosion Resistance 76 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

26 / 100
28 / 100

Formability (cold)

85 / 100
82 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 70 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC60800

C60800-O60 vs C60800-O61 — frequently asked

Is C60800-O61 stronger than C60800-O60?

Yes. C60800-O61 has a typical yield strength of 186 MPa (27 ksi) against 165 MPa (23.9 ksi) for C60800-O60 — about 13% more. Tensile strength is 415 MPa (60.2 ksi) vs 395 MPa (57.3 ksi).

Which condition does FabDigit quote by default, O60 or O61?

O61 is the default C60800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C60800-O60 over C60800-O61?

Pick C60800-O61 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C60800-O60 and C60800-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.