FabDigitFabDigit

Copper Alloy C60800-H80 vs C60800-O61

Copper Alloy · C60800 temper comparison

C60800-H80 and C60800-O61 are two conditions of the same copper alloy grade, C60800: H80 (hard drawn) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C60800-H80 is the stronger of the two: yield strength 400 MPa (58 ksi) against 186 MPa (27 ksi) for C60800-O61, about 115% more; tensile strength follows at 550 MPa (79.8 ksi) vs 415 MPa (60.2 ksi). In exchange, C60800-O61 is the more ductile: elongation 55% versus 15% for C60800-H80, and C60800-H80 is harder (158 HB vs 100 HB). C60800-O61 runs hotter in service (250°C vs 200°C continuous).

C60800-H80Choose it when strength drives the design.

C60800-O61Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C60800-H80 vs C60800-O61: properties

C60800-H80C60800-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
186 MPa27 ksi

Elongation at Break

15%
55%

Reduction in Area

40%
65%

Shear Strength

320 MPa46.4 ksi
255 MPa37 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
150 MPa21.8 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

158 HB
100 HB

Hardness, Rockwell B

82 HRB
55 HRB

Hardness, Vickers

165 HV
105 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 8.17 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,035°C1,895 °F · Liquidus Temperature 1,055°C1,931 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

80 W/m·K46.2 BTU/hr·ft·°F
82 W/m·K47.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

16.5 % IACS
17 % IACS

Electrical Resistivity

1.04×10⁻⁷ Ω·m4.09 µΩ·in
1.01×10⁻⁷ Ω·m3.98 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

73 / 100
76 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
20%

Weldability

65 / 100
70 / 100

Formability (cold)

35 / 100
82 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC60800

C60800-H80 vs C60800-O61 — frequently asked

Is C60800-H80 stronger than C60800-O61?

Yes. C60800-H80 has a typical yield strength of 400 MPa (58 ksi) against 186 MPa (27 ksi) for C60800-O61 — about 115% more. Tensile strength is 550 MPa (79.8 ksi) vs 415 MPa (60.2 ksi).

Which condition does FabDigit quote by default, H80 or O61?

O61 is the default C60800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C60800-H80 or C60800-O61?

C60800-H80, by a small margin. Both rate poor for machinability — 34/100 against 28/100 for C60800-O61; for welding the order is C60800-O61 first (very good, 70/100) then C60800-H80 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C60800-H80 and C60800-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.