FabDigitFabDigit

Copper Alloy C53800-H01 vs C53800-H10

Copper Alloy · C53800 temper comparison

C53800-H01 and C53800-H10 are two conditions of the same copper alloy grade, C53800: H01 (quarter hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C53800-H10 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 290 MPa (42.1 ksi) for C53800-H01, about 114% more; tensile strength follows at 690 MPa (100 ksi) vs 420 MPa (60.9 ksi). In exchange, C53800-H01 is the more ductile: elongation 25% versus 3% for C53800-H10, and C53800-H10 is harder (210 HB vs 118 HB). C53800-H01 runs hotter in service (200°C vs 150°C continuous).

C53800-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C53800-H10Choose it when strength drives the design.

C53800-H01 vs C53800-H10: properties

C53800-H01C53800-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

110 GPa16 Msi
113 GPa16.4 Msi

Tensile Strength (Ultimate)

420 MPa60.9 ksi
690 MPa100 ksi

Yield Strength (0.2% offset)

290 MPa42.1 ksi
620 MPa89.9 ksi

Elongation at Break

25%
3%

Shear Strength

275 MPa39.9 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
215 MPa31.2 ksi

Hardness, Brinell

118 HB
210 HB

Hardness, Rockwell B

68 HRB
97 HRB

Hardness, Vickers

124 HV
222 HV

Same in both: Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 930°C1,706 °F · Liquidus Temperature 1,025°C1,877 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Thermal Conductivity 69 W/m·K39.9 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.8 µm/m·K9.9 µin/in·°F · Latent Heat of Fusion 195 J/g83.8 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 15 % IACS · Electrical Resistivity 1.15×10⁻⁷ Ω·m4.53 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
80%

Formability (cold)

55 / 100
15 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC53800

C53800-H01 vs C53800-H10 — frequently asked

Is C53800-H10 stronger than C53800-H01?

Yes. C53800-H10 has a typical yield strength of 620 MPa (89.9 ksi) against 290 MPa (42.1 ksi) for C53800-H01 — about 114% more. Tensile strength is 690 MPa (100 ksi) vs 420 MPa (60.9 ksi).

Which condition does FabDigit quote by default, H01 or H10?

H04 is the default C53800 condition in the FabDigit quote flow (neither H01 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C53800-H01 or C53800-H10?

C53800-H10, by a small margin. Both rate very good for machinability — 80/100 against 75/100 for C53800-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C53800-H01 and C53800-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.