Copper Alloy C53800-H01 vs C53800-H02
Copper Alloy · C53800 temper comparison
C53800-H01 and C53800-H02 are two conditions of the same copper alloy grade, C53800: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C53800-H02 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 290 MPa (42.1 ksi) for C53800-H01, about 31% more; tensile strength follows at 480 MPa (69.6 ksi) vs 420 MPa (60.9 ksi). In exchange, C53800-H01 is the more ductile: elongation 25% versus 15% for C53800-H02, and C53800-H02 is harder (145 HB vs 118 HB).
C53800-H01Choose it when the part is bent, formed or impact-loaded.
C53800-H02Choose it when strength drives the design.
C53800-H01 vs C53800-H02: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34
Physical
Density and transition temperatures.
Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 930°C1,706 °F · Liquidus Temperature 1,025°C1,877 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 69 W/m·K39.9 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.8 µm/m·K9.9 µin/in·°F · Latent Heat of Fusion 195 J/g83.8 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 15 % IACS · Electrical Resistivity 1.15×10⁻⁷ Ω·m4.53 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 70 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Formability (cold)
Same in both: Weldability 20 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C53800-H01 vs C53800-H02 — frequently asked
Is C53800-H02 stronger than C53800-H01?
Yes. C53800-H02 has a typical yield strength of 380 MPa (55.1 ksi) against 290 MPa (42.1 ksi) for C53800-H01 — about 31% more. Tensile strength is 480 MPa (69.6 ksi) vs 420 MPa (60.9 ksi).
Which condition does FabDigit quote by default, H01 or H02?
H04 is the default C53800 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, C53800-H01 or C53800-H02?
C53800-H02, by a small margin. Both rate very good for machinability — 80/100 against 75/100 for C53800-H01.
Ready to make it?
Upload a CAD file and FabDigit prices the part in C53800-H01 and C53800-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
