FabDigitFabDigit

Copper Alloy C50700-H01 vs C50700-H06

Copper Alloy · C50700 temper comparison

C50700-H01 and C50700-H06 are two conditions of the same copper alloy grade, C50700: H01 (quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C50700-H06 is the stronger of the two: yield strength 475 MPa (68.9 ksi) against 270 MPa (39.2 ksi) for C50700-H01, about 76% more; tensile strength follows at 520 MPa (75.4 ksi) vs 350 MPa (50.8 ksi). In exchange, C50700-H01 is the more ductile: elongation 25% versus 5% for C50700-H06, and C50700-H06 is harder (158 HB vs 103 HB). C50700-H01 runs hotter in service (200°C vs 160°C continuous).

C50700-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C50700-H06Choose it when strength drives the design.

C50700-H01 vs C50700-H06: properties

C50700-H01C50700-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

350 MPa50.8 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

270 MPa39.2 ksi
475 MPa68.9 ksi

Elongation at Break

25%
5%

Reduction in Area

40%
15%

Compressive Strength

280 MPa40.6 ksi
485 MPa70.3 ksi

Shear Strength

215 MPa31.2 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
185 MPa26.8 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

103 HB
158 HB

Hardness, Rockwell B

57 HRB
84 HRB

Hardness, Vickers

107 HV
167 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 122 GPa17.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,025°C1,877 °F · Liquidus Temperature 1,060°C1,940 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
160°C320 °F

Same in both: Thermal Conductivity 130 W/m·K75.1 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.8 µm/m·K9.9 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

32 % IACS
30 % IACS

Electrical Resistivity

5.4×10⁻⁸ Ω·m2.13 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
22%

Formability (cold)

75 / 100
40 / 100

Same in both: Weldability 35 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC50700

C50700-H01 vs C50700-H06 — frequently asked

Is C50700-H06 stronger than C50700-H01?

Yes. C50700-H06 has a typical yield strength of 475 MPa (68.9 ksi) against 270 MPa (39.2 ksi) for C50700-H01 — about 76% more. Tensile strength is 520 MPa (75.4 ksi) vs 350 MPa (50.8 ksi).

Which condition does FabDigit quote by default, H01 or H06?

H08 is the default C50700 condition in the FabDigit quote flow (neither H01 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C50700-H01 or C50700-H06?

C50700-H06, by a small margin. Both rate poor for machinability — 33/100 against 25/100 for C50700-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C50700-H01 and C50700-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.