C47940-H04 and C47940-O60 are two conditions of the same copper alloy grade, C47940: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C47940-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 140 MPa (20.3 ksi) for C47940-O60, about 196% more; tensile strength follows at 550 MPa (79.8 ksi) vs 380 MPa (55.1 ksi). In exchange, C47940-O60 is the more ductile: elongation 48% versus 14% for C47940-H04, and C47940-H04 is harder (165 HB vs 85 HB). C47940-O60 runs hotter in service (200°C vs 160°C continuous). On the shop floor, C47940-H04 machines more easily (good vs fair).

C47940-H04Choose it when strength drives the design, or when the part is machined in volume.

C47940-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C47940-H04 vs C47940-O60: properties

C47940-H04C47940-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

550 MPa79.8 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
140 MPa20.3 ksi

Elongation at Break

14%
48%

Reduction in Area

32%
60%

Shear Strength

330 MPa47.9 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
125 MPa18.1 ksi

Hardness, Brinell

165 HB
85 HB

Hardness, Rockwell B

85 HRB
40 HRB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 45 J33.2 ft·lbf · Hardness, Vickers 112 HV

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

160°C320 °F
200°C392 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.9 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

62 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

62%
45%

Formability (cold)

20 / 100
70 / 100

Same in both: Weldability 25 / 100 · Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC47940

C47940-H04 vs C47940-O60 — frequently asked

Is C47940-H04 stronger than C47940-O60?

Yes. C47940-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 140 MPa (20.3 ksi) for C47940-O60 — about 196% more. Tensile strength is 550 MPa (79.8 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, H04 or O60?

M30 is the default C47940 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C47940-H04 or C47940-O60?

C47940-H04. Its machinability rates good (62/100) against fair (45/100) for C47940-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C47940-H04 and C47940-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.