FabDigitFabDigit

Copper Alloy C46500-H06 vs C46500-H80

Copper Alloy · C46500 temper comparison

C46500-H06 and C46500-H80 are two conditions of the same copper alloy grade, C46500: H06 (extra hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C46500-H06 is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 380 MPa (55.1 ksi) for C46500-H80, about 24% more; tensile strength follows at 620 MPa (89.9 ksi) vs 540 MPa (78.3 ksi). In exchange, C46500-H80 is the more ductile: elongation 15% versus 10% for C46500-H06, and C46500-H06 is harder (175 HB vs 145 HB). C46500-H80 runs hotter in service (160°C vs 140°C continuous).

C46500-H06Choose it when strength drives the design.

C46500-H80Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C46500-H06 vs C46500-H80: properties

C46500-H06C46500-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
102 GPa14.8 Msi

Tensile Strength (Ultimate)

620 MPa89.9 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

470 MPa68.2 ksi
380 MPa55.1 ksi

Elongation at Break

10%
15%

Reduction in Area

32%
42%

Shear Strength

350 MPa50.8 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
165 MPa23.9 ksi

Charpy V-Notch Impact (RT)

16 J11.8 ft·lbf
24 J17.7 ft·lbf

Hardness, Brinell

175 HB
145 HB

Hardness, Rockwell B

88 HRB
78 HRB

Same in both: Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

140°C284 °F
160°C320 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
26 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
6.7×10⁻⁸ Ω·m2.64 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

35%
32%

Weldability

38 / 100
40 / 100

Formability (cold)

15 / 100
30 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC46500

C46500-H06 vs C46500-H80 — frequently asked

Is C46500-H06 stronger than C46500-H80?

Yes. C46500-H06 has a typical yield strength of 470 MPa (68.2 ksi) against 380 MPa (55.1 ksi) for C46500-H80 — about 24% more. Tensile strength is 620 MPa (89.9 ksi) vs 540 MPa (78.3 ksi).

Which condition does FabDigit quote by default, H06 or H80?

M20 is the default C46500 condition in the FabDigit quote flow (neither H06 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C46500-H06 over C46500-H80?

Pick C46500-H06 when strength drives the design. Pick C46500-H80 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C46500-H06 and C46500-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.