FabDigitFabDigit

Copper Alloy C46500-H02 vs C46500-M30

Copper Alloy · C46500 temper comparison

C46500-H02 and C46500-M30 are two conditions of the same copper alloy grade, C46500: H02 (half hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C46500-H02 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 170 MPa (24.7 ksi) for C46500-M30, about 100% more; tensile strength follows at 480 MPa (69.6 ksi) vs 380 MPa (55.1 ksi). In exchange, C46500-M30 is the more ductile: elongation 40% versus 20% for C46500-H02, and C46500-H02 is harder (130 HB vs 92 HB). C46500-M30 runs hotter in service (200°C vs 160°C continuous).

C46500-H02Choose it when strength drives the design.

C46500-M30Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C46500-H02 vs C46500-M30: properties

C46500-H02C46500-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

480 MPa69.6 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
170 MPa24.7 ksi

Elongation at Break

20%
40%

Reduction in Area

50%
55%

Shear Strength

305 MPa44.2 ksi
255 MPa37 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
130 MPa18.9 ksi

Charpy V-Notch Impact (RT)

45 J33.2 ft·lbf
50 J36.9 ft·lbf

Hardness, Brinell

130 HB
92 HB

Hardness, Rockwell B

75 HRB
50 HRB

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

160°C320 °F
200°C392 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 64 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

34%
30%

Formability (cold)

38 / 100
60 / 100

Same in both: Machinability 32 / 100 · Weldability 45 / 100 · Castability 55 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC46500

C46500-H02 vs C46500-M30 — frequently asked

Is C46500-H02 stronger than C46500-M30?

Yes. C46500-H02 has a typical yield strength of 340 MPa (49.3 ksi) against 170 MPa (24.7 ksi) for C46500-M30 — about 100% more. Tensile strength is 480 MPa (69.6 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, H02 or M30?

M20 is the default C46500 condition in the FabDigit quote flow (neither H02 nor M30). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C46500-H02 over C46500-M30?

Pick C46500-H02 when strength drives the design. Pick C46500-M30 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C46500-H02 and C46500-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.