FabDigitFabDigit

Copper Alloy C46400-H04 vs C46400-M10

Copper Alloy · C46400 temper comparison

C46400-H04 and C46400-M10 are two conditions of the same copper alloy grade, C46400: H04 (full hard) versus M10 (as hot forged and air cooled). The chemistry is identical, so every difference below comes from the condition. C46400-H04 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 170 MPa (24.7 ksi) for C46400-M10, about 124% more; tensile strength follows at 550 MPa (79.8 ksi) vs 390 MPa (56.6 ksi). In exchange, C46400-M10 is the more ductile: elongation 40% versus 17% for C46400-H04, and C46400-H04 is harder (150 HB vs 95 HB). C46400-M10 runs hotter in service (200°C vs 150°C continuous). On the shop floor, C46400-M10 machines more easily (good vs fair).

C46400-H04Choose it when strength drives the design.

C46400-M10Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C46400-H04 vs C46400-M10: properties

C46400-H04C46400-M10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Bulk Modulus

111 GPa16.1 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

550 MPa79.8 ksi
390 MPa56.6 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
170 MPa24.7 ksi

Elongation at Break

17%
40%

Reduction in Area

35%
50%

Shear Strength

350 MPa50.8 ksi
275 MPa39.9 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
140 MPa20.3 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
45 J33.2 ft·lbf

Hardness, Brinell

150 HB
95 HB

Hardness, Rockwell B

75 HRB
60 HRB

Hardness, Vickers

158 HV
100 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 37 GPa5.4 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Latent Heat of Fusion

168 J/g72.2 BTU/lb
175 J/g75.2 BTU/lb

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
26 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
90%

Weldability

40 / 100
45 / 100

Formability (cold)

20 / 100
60 / 100

Brazeability / Solderability

90 / 100
85 / 100

Polishability

75 / 100
80 / 100

Same in both: Castability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

60 MJ/kg25,795 BTU/lb
55 MJ/kg23,646 BTU/lb

Embodied Carbon (primary production)

3.8 kg CO₂/kg
3.6 kg CO₂/kg

Typical Recycled Content

50%
40%

Same in both: Embodied Water 300 L/kg35.9 gal/lb

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC46400

C46400-H04 vs C46400-M10 — frequently asked

Is C46400-H04 stronger than C46400-M10?

Yes. C46400-H04 has a typical yield strength of 380 MPa (55.1 ksi) against 170 MPa (24.7 ksi) for C46400-M10 — about 124% more. Tensile strength is 550 MPa (79.8 ksi) vs 390 MPa (56.6 ksi).

Which condition does FabDigit quote by default, H04 or M10?

O is the default C46400 condition in the FabDigit quote flow (neither H04 nor M10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C46400-H04 or C46400-M10?

C46400-M10. Its machinability rates good (60/100) against fair (38/100) for C46400-H04; for welding the order is C46400-M10 first (fair, 45/100) then C46400-H04 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C46400-H04 and C46400-M10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.