FabDigitFabDigit

Copper Alloy C43000-H01 vs C43000-H04

Copper Alloy · C43000 temper comparison

C43000-H01 and C43000-H04 are two conditions of the same copper alloy grade, C43000: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C43000-H04 is the stronger of the two: yield strength 470 MPa (68.2 ksi) against 310 MPa (45 ksi) for C43000-H01, about 52% more; tensile strength follows at 540 MPa (78.3 ksi) vs 400 MPa (58 ksi). In exchange, C43000-H01 is the more ductile: elongation 32% versus 7% for C43000-H04, and C43000-H04 is harder (170 HV vs 118 HV).

C43000-H01Choose it when the part is bent, formed or impact-loaded.

C43000-H04Choose it when strength drives the design.

C43000-H01 vs C43000-H04: properties

C43000-H01C43000-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
470 MPa68.2 ksi

Elongation at Break

32%
7%

Shear Strength

265 MPa38.4 ksi
340 MPa49.3 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
200 MPa29 ksi

Hardness, Rockwell B

62 HRB
82 HRB

Hardness, Vickers

118 HV
170 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33 · Hardness, Brinell 130 HB

Physical

Density and transition temperatures.

Same in both: Density 8.53 g/cm³0.31 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 110 W/m·K63.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.1 µm/m·K10.6 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
24 % IACS

Same in both: Electrical Resistivity 6.9×10⁻⁸ Ω·m2.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
36 / 100

Formability (cold)

80 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 55 / 100 · Castability 35 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 3.7 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC43000

C43000-H01 vs C43000-H04 — frequently asked

Is C43000-H04 stronger than C43000-H01?

Yes. C43000-H04 has a typical yield strength of 470 MPa (68.2 ksi) against 310 MPa (45 ksi) for C43000-H01 — about 52% more. Tensile strength is 540 MPa (78.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C43000 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C43000-H01 or C43000-H04?

C43000-H04. Its machinability rates fair (36/100) against poor (30/100) for C43000-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C43000-H01 and C43000-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.