FabDigitFabDigit

Copper Alloy C36200-H04 vs C36200-O60

Copper Alloy · C36200 temper comparison

C36200-H04 and C36200-O60 are two conditions of the same copper alloy grade, C36200: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C36200-H04 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 125 MPa (18.1 ksi) for C36200-O60, about 196% more; tensile strength follows at 450 MPa (65.3 ksi) vs 320 MPa (46.4 ksi). In exchange, C36200-O60 is the more ductile: elongation 55% versus 15% for C36200-H04, and C36200-H04 is harder (135 HB vs 68 HB). C36200-O60 runs hotter in service (250°C vs 180°C continuous). On the shop floor, C36200-H04 machines more easily (100 vs 90 out of 100).

C36200-H04Choose it when strength drives the design, or when the part is machined in volume.

C36200-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C36200-H04 vs C36200-O60: properties

C36200-H04C36200-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
125 MPa18.1 ksi

Elongation at Break

15%
55%

Shear Strength

275 MPa39.9 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

138 MPa20 ksi
105 MPa15.2 ksi

Hardness, Brinell

135 HB
68 HB

Hardness, Rockwell B

85 HRB
30 HRB

Hardness, Vickers

142 HV
72 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

180°C356 °F
250°C482 °F

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
27 % IACS

Same in both: Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

100 / 100
90 / 100

Formability (cold)

12 / 100
35 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 300% · Weldability 15 / 100 · Brazeability / Solderability 70 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 75%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC36200

C36200-H04 vs C36200-O60 — frequently asked

Is C36200-H04 stronger than C36200-O60?

Yes. C36200-H04 has a typical yield strength of 370 MPa (53.7 ksi) against 125 MPa (18.1 ksi) for C36200-O60 — about 196% more. Tensile strength is 450 MPa (65.3 ksi) vs 320 MPa (46.4 ksi).

Which condition does FabDigit quote by default, H04 or O60?

H02 is the default C36200 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C36200-H04 or C36200-O60?

C36200-H04, by a small margin. Both rate excellent for machinability — 100/100 against 90/100 for C36200-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C36200-H04 and C36200-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.