FabDigitFabDigit

Copper Alloy C36000-H04 vs C36000-M30

Copper Alloy · C36000 temper comparison

C36000-H04 and C36000-M30 are two conditions of the same copper alloy grade, C36000: H04 (full hard) versus M30 (as hot extruded). The chemistry is identical, so every difference below comes from the condition. C36000-H04 is the stronger of the two: yield strength 400 MPa (58 ksi) against 125 MPa (18.1 ksi) for C36000-M30, about 3.2 times as much; tensile strength follows at 470 MPa (68.2 ksi) vs 340 MPa (49.3 ksi). In exchange, C36000-M30 is the more ductile: elongation 45% versus 12% for C36000-H04, and C36000-H04 is harder (140 HB vs 85 HB). C36000-M30 runs hotter in service (200°C vs 180°C continuous).

C36000-H04Choose it when strength drives the design.

C36000-M30Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C36000-H04 vs C36000-M30: properties

C36000-H04C36000-M30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
125 MPa18.1 ksi

Elongation at Break

12%
45%

Reduction in Area

33%
50%

Shear Strength

280 MPa40.6 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
105 MPa15.2 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

140 HB
85 HB

Hardness, Rockwell B

85 HRB
60 HRB

Hardness, Vickers

148 HV
90 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.31

Physical

Density and transition temperatures.

Same in both: Density 8.5 g/cm³0.31 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

114 W/m·K65.9 BTU/hr·ft·°F
115 W/m·K66.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

25 % IACS
27 % IACS

Electrical Resistivity

6.9×10⁻⁸ Ω·m2.72 µΩ·in
6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

50 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

100 / 100
95 / 100

Machinability Rating (AISI 1212 = 100 %)

300%
285%

Weldability

18 / 100
20 / 100

Formability (cold)

12 / 100
35 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 85 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 220 L/kg26.4 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC36000

C36000-H04 vs C36000-M30 — frequently asked

Is C36000-H04 stronger than C36000-M30?

Yes. C36000-H04 has a typical yield strength of 400 MPa (58 ksi) against 125 MPa (18.1 ksi) for C36000-M30 — about 3.2 times as much. Tensile strength is 470 MPa (68.2 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, H04 or M30?

H02 is the default C36000 condition in the FabDigit quote flow (neither H04 nor M30). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C36000-H04 or C36000-M30?

C36000-H04, by a small margin. Both rate excellent for machinability — 100/100 against 95/100 for C36000-M30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C36000-H04 and C36000-M30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.