FabDigitFabDigit

Copper Alloy C35600-H01 vs C35600-O60

Copper Alloy · C35600 temper comparison

C35600-H01 and C35600-O60 are two conditions of the same copper alloy grade, C35600: H01 (quarter hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C35600-H01 is the stronger of the two: yield strength 270 MPa (39.2 ksi) against 115 MPa (16.7 ksi) for C35600-O60, about 135% more; tensile strength follows at 395 MPa (57.3 ksi) vs 340 MPa (49.3 ksi). In exchange, C35600-O60 is the more ductile: elongation 50% versus 25% for C35600-H01, and C35600-H01 is harder (115 HV vs 80 HV).

C35600-H01Choose it when strength drives the design.

C35600-O60Choose it when the part is bent, formed or impact-loaded.

C35600-H01 vs C35600-O60: properties

C35600-H01C35600-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

270 MPa39.2 ksi
115 MPa16.7 ksi

Elongation at Break

25%
50%

Shear Strength

265 MPa38.4 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

140 MPa20.3 ksi
125 MPa18.1 ksi

Hardness, Rockwell B

62 HRB
42 HRB

Hardness, Vickers

115 HV
80 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34 · Hardness, Brinell 125 HB

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 899°C1,650 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

190°C374 °F
200°C392 °F

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

95 / 100
90 / 100

Formability (cold)

60 / 100
75 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 100% · Weldability 20 / 100 · Castability 60 / 100 · Brazeability / Solderability 85 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC35600

C35600-H01 vs C35600-O60 — frequently asked

Is C35600-H01 stronger than C35600-O60?

Yes. C35600-H01 has a typical yield strength of 270 MPa (39.2 ksi) against 115 MPa (16.7 ksi) for C35600-O60 — about 135% more. Tensile strength is 395 MPa (57.3 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, H01 or O60?

H02 is the default C35600 condition in the FabDigit quote flow (neither H01 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C35600-H01 or C35600-O60?

C35600-H01, by a small margin. Both rate excellent for machinability — 95/100 against 90/100 for C35600-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C35600-H01 and C35600-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.