FabDigitFabDigit

Copper Alloy C35000-H01 vs C35000-H04

Copper Alloy · C35000 temper comparison

C35000-H01 and C35000-H04 are two conditions of the same copper alloy grade, C35000: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C35000-H04 is the stronger of the two: yield strength 395 MPa (57.3 ksi) against 275 MPa (39.9 ksi) for C35000-H01, about 44% more; tensile strength follows at 483 MPa (70.1 ksi) vs 372 MPa (54 ksi). In exchange, C35000-H01 is the more ductile: elongation 30% versus 7% for C35000-H04, and C35000-H04 is harder (140 HB vs 95 HB). C35000-H01 runs hotter in service (175°C vs 150°C continuous).

C35000-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C35000-H04Choose it when strength drives the design.

C35000-H01 vs C35000-H04: properties

C35000-H01C35000-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

372 MPa54 ksi
483 MPa70.1 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
395 MPa57.3 ksi

Elongation at Break

30%
7%

Shear Strength

250 MPa36.3 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

145 MPa21 ksi
165 MPa23.9 ksi

Hardness, Brinell

95 HB
140 HB

Hardness, Rockwell B

55 HRB
80 HRB

Hardness, Vickers

105 HV
150 HV

Same in both: Elastic (Young's) Modulus 97 GPa14.1 Msi · Shear Modulus 37 GPa5.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 888°C1,630 °F · Liquidus Temperature 899°C1,650 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 115 W/m·K66.4 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 48 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
78 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
75%

Formability (cold)

72 / 100
35 / 100

Same in both: Weldability 20 / 100 · Castability 45 / 100 · Brazeability / Solderability 70 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC35000

C35000-H01 vs C35000-H04 — frequently asked

Is C35000-H04 stronger than C35000-H01?

Yes. C35000-H04 has a typical yield strength of 395 MPa (57.3 ksi) against 275 MPa (39.9 ksi) for C35000-H01 — about 44% more. Tensile strength is 483 MPa (70.1 ksi) vs 372 MPa (54 ksi).

Which condition does FabDigit quote by default, H01 or H04?

H02 is the default C35000 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C35000-H01 or C35000-H04?

C35000-H04, by a small margin. Both rate very good for machinability — 78/100 against 72/100 for C35000-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C35000-H01 and C35000-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.