FabDigitFabDigit

Copper Alloy C32000-H02 vs C32000-O60

Copper Alloy · C32000 temper comparison

C32000-H02 and C32000-O60 are two conditions of the same copper alloy grade, C32000: H02 (half hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C32000-H02 is the stronger of the two: yield strength 270 MPa (39.2 ksi) against 95 MPa (13.8 ksi) for C32000-O60, about 184% more; tensile strength follows at 350 MPa (50.8 ksi) vs 275 MPa (39.9 ksi). In exchange, C32000-O60 is the more ductile: elongation 55% versus 25% for C32000-H02, and C32000-H02 is harder (100 HB vs 55 HB). C32000-O60 runs hotter in service (200°C vs 180°C continuous). On the shop floor, C32000-H02 machines more easily (80 vs 70 out of 100).

C32000-H02Choose it when strength drives the design, or when the part is machined in volume.

C32000-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C32000-H02 vs C32000-O60: properties

C32000-H02C32000-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

350 MPa50.8 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

270 MPa39.2 ksi
95 MPa13.8 ksi

Elongation at Break

25%
55%

Shear Strength

230 MPa33.4 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
105 MPa15.2 ksi

Hardness, Brinell

100 HB
55 HB

Hardness, Rockwell B

55 HRB
20 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 120 GPa17.4 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 980°C1,796 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

151 W/m·K87.2 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.7 µm/m·K10.4 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
37 % IACS

Same in both: Electrical Resistivity 4.8×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

80 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

80%
70%

Formability (cold)

55 / 100
85 / 100

Same in both: Weldability 20 / 100 · Castability 60 / 100 · Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC32000

C32000-H02 vs C32000-O60 — frequently asked

Is C32000-H02 stronger than C32000-O60?

Yes. C32000-H02 has a typical yield strength of 270 MPa (39.2 ksi) against 95 MPa (13.8 ksi) for C32000-O60 — about 184% more. Tensile strength is 350 MPa (50.8 ksi) vs 275 MPa (39.9 ksi).

Which condition does FabDigit quote by default, H02 or O60?

H02 is the default C32000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C32000-H02 or C32000-O60?

C32000-H02, by a small margin. Both rate very good for machinability — 80/100 against 70/100 for C32000-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C32000-H02 and C32000-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.