FabDigitFabDigit

Copper Alloy C31400-H06 vs C31400-O60

Copper Alloy · C31400 temper comparison

C31400-H06 and C31400-O60 are two conditions of the same copper alloy grade, C31400: H06 (extra hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C31400-H06 is the stronger of the two: yield strength 400 MPa (58 ksi) against 90 MPa (13.1 ksi) for C31400-O60, about 4.4 times as much; tensile strength follows at 455 MPa (66 ksi) vs 255 MPa (37 ksi). In exchange, C31400-O60 is the more ductile: elongation 45% versus 6% for C31400-H06, and C31400-H06 is harder (140 HB vs 55 HB). C31400-O60 runs hotter in service (250°C vs 150°C continuous). On the shop floor, C31400-H06 machines more easily (82 vs 72 out of 100).

C31400-H06Choose it when strength drives the design, or when the part is machined in volume.

C31400-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C31400-H06 vs C31400-O60: properties

C31400-H06C31400-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

455 MPa66 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
90 MPa13.1 ksi

Elongation at Break

6%
45%

Reduction in Area

25%
60%

Shear Strength

275 MPa39.9 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
95 MPa13.8 ksi

Hardness, Brinell

140 HB
55 HB

Hardness, Rockwell B

78 HRB
25 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,010°C1,850 °F · Liquidus Temperature 1,035°C1,895 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

180 W/m·K104 BTU/hr·ft·°F
183 W/m·K106 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
43 % IACS

Electrical Resistivity

4.2×10⁻⁸ Ω·m1.65 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

82 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

132%
115%

Weldability

20 / 100
25 / 100

Formability (cold)

25 / 100
90 / 100

Same in both: Castability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC31400

C31400-H06 vs C31400-O60 — frequently asked

Is C31400-H06 stronger than C31400-O60?

Yes. C31400-H06 has a typical yield strength of 400 MPa (58 ksi) against 90 MPa (13.1 ksi) for C31400-O60 — about 4.4 times as much. Tensile strength is 455 MPa (66 ksi) vs 255 MPa (37 ksi).

Which condition does FabDigit quote by default, H06 or O60?

H02 is the default C31400 condition in the FabDigit quote flow (neither H06 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C31400-H06 or C31400-O60?

C31400-H06, by a small margin. Both rate very good for machinability — 82/100 against 72/100 for C31400-O60; for welding the order is C31400-O60 first (poor, 25/100) then C31400-H06 (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C31400-H06 and C31400-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.