FabDigitFabDigit

Copper Alloy C31400-H01 vs C31400-O60

Copper Alloy · C31400 temper comparison

C31400-H01 and C31400-O60 are two conditions of the same copper alloy grade, C31400: H01 (quarter hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C31400-H01 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 90 MPa (13.1 ksi) for C31400-O60, about 117% more; tensile strength follows at 305 MPa (44.2 ksi) vs 255 MPa (37 ksi). In exchange, C31400-O60 is the more ductile: elongation 45% versus 28% for C31400-H01, and C31400-H01 is harder (85 HB vs 55 HB). C31400-O60 runs hotter in service (250°C vs 200°C continuous).

C31400-H01Choose it when strength drives the design.

C31400-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C31400-H01 vs C31400-O60: properties

C31400-H01C31400-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

305 MPa44.2 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

195 MPa28.3 ksi
90 MPa13.1 ksi

Elongation at Break

28%
45%

Reduction in Area

50%
60%

Shear Strength

215 MPa31.2 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
95 MPa13.8 ksi

Hardness, Brinell

85 HB
55 HB

Hardness, Rockwell B

50 HRB
25 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,010°C1,850 °F · Liquidus Temperature 1,035°C1,895 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

180 W/m·K104 BTU/hr·ft·°F
183 W/m·K106 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

4×10⁻⁸ Ω·m1.57 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Same in both: Electrical Conductivity 43 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

128%
115%

Formability (cold)

78 / 100
90 / 100

Same in both: Weldability 25 / 100 · Castability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC31400

C31400-H01 vs C31400-O60 — frequently asked

Is C31400-H01 stronger than C31400-O60?

Yes. C31400-H01 has a typical yield strength of 195 MPa (28.3 ksi) against 90 MPa (13.1 ksi) for C31400-O60 — about 117% more. Tensile strength is 305 MPa (44.2 ksi) vs 255 MPa (37 ksi).

Which condition does FabDigit quote by default, H01 or O60?

H02 is the default C31400 condition in the FabDigit quote flow (neither H01 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C31400-H01 or C31400-O60?

C31400-H01, by a small margin. Both rate very good for machinability — 78/100 against 72/100 for C31400-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C31400-H01 and C31400-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.