FabDigitFabDigit

Copper Alloy C28000-H01 vs C28000-H04

Copper Alloy · C28000 temper comparison

C28000-H01 and C28000-H04 are two conditions of the same copper alloy grade, C28000: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C28000-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 275 MPa (39.9 ksi) for C28000-H01, about 51% more; tensile strength follows at 500 MPa (72.5 ksi) vs 400 MPa (58 ksi). In exchange, C28000-H01 is the more ductile: elongation 25% versus 6% for C28000-H04, and C28000-H04 is harder (150 HB vs 105 HB). C28000-H01 runs hotter in service (150°C vs 120°C continuous).

C28000-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C28000-H04Choose it when strength drives the design.

C28000-H01 vs C28000-H04: properties

C28000-H01C28000-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
415 MPa60.2 ksi

Elongation at Break

25%
6%

Shear Strength

275 MPa39.9 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
170 MPa24.7 ksi

Hardness, Brinell

105 HB
150 HB

Hardness, Rockwell B

60 HRB
82 HRB

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.39 g/cm³0.3 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 905°C1,661 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Thermal Conductivity 123 W/m·K71.1 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.8 µm/m·K11.6 µin/in·°F · Latent Heat of Fusion 160 J/g68.8 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 27 % IACS · Electrical Resistivity 6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

43 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

58 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
45%

Weldability

50 / 100
45 / 100

Formability (cold)

40 / 100
20 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 85 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 48 MJ/kg20,636 BTU/lb · Embodied Carbon (primary production) 3 kg CO₂/kg · Embodied Water 200 L/kg24 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC28000

C28000-H01 vs C28000-H04 — frequently asked

Is C28000-H04 stronger than C28000-H01?

Yes. C28000-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 275 MPa (39.9 ksi) for C28000-H01 — about 51% more. Tensile strength is 500 MPa (72.5 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H01 or H04?

O is the default C28000 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C28000-H01 or C28000-H04?

C28000-H01. Its weldability rates fair (50/100) against fair (45/100) for C28000-H04.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C28000-H01 and C28000-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.