FabDigitFabDigit

Copper Alloy C22600-H02 vs C22600-H10

Copper Alloy · C22600 temper comparison

C22600-H02 and C22600-H10 are two conditions of the same copper alloy grade, C22600: H02 (half hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C22600-H10 is the stronger of the two: yield strength 503 MPa (73 ksi) against 330 MPa (47.9 ksi) for C22600-H02, about 52% more; tensile strength follows at 579 MPa (84 ksi) vs 400 MPa (58 ksi). In exchange, C22600-H02 is the more ductile: elongation 12% versus 3% for C22600-H10, and C22600-H10 is harder (162 HB vs 105 HB). C22600-H02 runs hotter in service (200°C vs 150°C continuous).

C22600-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C22600-H10Choose it when strength drives the design.

C22600-H02 vs C22600-H10: properties

C22600-H02C22600-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
579 MPa84 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
503 MPa73 ksi

Elongation at Break

12%
3%

Shear Strength

262 MPa38 ksi
355 MPa51.5 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
205 MPa29.7 ksi

Hardness, Brinell

105 HB
162 HB

Hardness, Rockwell B

60 HRB
85 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 118 GPa17.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,005°C1,841 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Thermal Conductivity 172 W/m·K99.4 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
38 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.23 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
36 / 100

Formability (cold)

72 / 100
22 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 55 / 100 · Castability 35 / 100 · Brazeability / Solderability 92 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 290 L/kg34.7 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC22600

C22600-H02 vs C22600-H10 — frequently asked

Is C22600-H10 stronger than C22600-H02?

Yes. C22600-H10 has a typical yield strength of 503 MPa (73 ksi) against 330 MPa (47.9 ksi) for C22600-H02 — about 52% more. Tensile strength is 579 MPa (84 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H02 or H10?

H02 is the default C22600 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C22600-H02 over C22600-H10?

Pick C22600-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C22600-H10 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C22600-H02 and C22600-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.