FabDigitFabDigit

Copper Alloy C21000-H04 vs C21000-H06

Copper Alloy · C21000 temper comparison

C21000-H04 and C21000-H06 are two conditions of the same copper alloy grade, C21000: H04 (full hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C21000-H06 is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 340 MPa (49.3 ksi) for C21000-H04, about 13% more; tensile strength follows at 420 MPa (60.9 ksi) vs 380 MPa (55.1 ksi). In exchange, C21000-H04 is the more ductile: elongation 5% versus 4% for C21000-H06, and C21000-H06 is harder (115 HB vs 105 HB).

C21000-H04Choose it when the part is bent, formed or impact-loaded.

C21000-H06Choose it when strength drives the design.

C21000-H04 vs C21000-H06: properties

C21000-H04C21000-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

380 MPa55.1 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
385 MPa55.8 ksi

Elongation at Break

5%
4%

Shear Strength

225 MPa32.6 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
145 MPa21 ksi

Hardness, Brinell

105 HB
115 HB

Hardness, Vickers

115 HV
50 HV

Same in both: Elastic (Young's) Modulus 115 GPa16.7 Msi · Shear Modulus 43 GPa6.2 Msi · Bulk Modulus 128 GPa18.6 Msi · Poisson's Ratio 0.34 · Reduction in Area 70%

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,055°C1,931 °F · Liquidus Temperature 1,066°C1,951 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

130°C266 °F
120°C248 °F

Same in both: Thermal Conductivity 226 W/m·K131 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.1 µm/m·K10.1 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 54 % IACS · Electrical Resistivity 3.08×10⁻⁸ Ω·m1.21 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
32%

Formability (cold)

45 / 100
35 / 100

Same in both: Machinability 22 / 100 · Weldability 60 / 100 · Castability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 90 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC21000

C21000-H04 vs C21000-H06 — frequently asked

Is C21000-H06 stronger than C21000-H04?

Yes. C21000-H06 has a typical yield strength of 385 MPa (55.8 ksi) against 340 MPa (49.3 ksi) for C21000-H04 — about 13% more. Tensile strength is 420 MPa (60.9 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, H04 or H06?

OS050 is the default C21000 condition in the FabDigit quote flow (neither H04 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C21000-H04 over C21000-H06?

Pick C21000-H04 when the part is bent, formed or impact-loaded. Pick C21000-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C21000-H04 and C21000-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.