FabDigitFabDigit

Copper Alloy C19800-H02 vs C19800-H08

Copper Alloy · C19800 temper comparison

C19800-H02 and C19800-H08 are two conditions of the same copper alloy grade, C19800: H02 (half hard) versus H08 (spring hard). The chemistry is identical, so every difference below comes from the condition. C19800-H08 is the stronger of the two: yield strength 595 MPa (86.3 ksi) against 415 MPa (60.2 ksi) for C19800-H02, about 43% more; tensile strength follows at 615 MPa (89.2 ksi) vs 455 MPa (66 ksi). In exchange, C19800-H02 is the more ductile: elongation 8% versus 2% for C19800-H08, and C19800-H08 is harder (192 HV vs 148 HV). C19800-H02 runs hotter in service (160°C vs 130°C continuous). On the shop floor, C19800-H02 welds better (45 vs 35 out of 100).

C19800-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19800-H08Choose it when strength drives the design.

C19800-H02 vs C19800-H08: properties

C19800-H02C19800-H08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

120 GPa17.4 Msi
125 GPa18.1 Msi

Tensile Strength (Ultimate)

455 MPa66 ksi
615 MPa89.2 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
595 MPa86.3 ksi

Elongation at Break

8%
2%

Shear Strength

295 MPa42.8 ksi
375 MPa54.4 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
220 MPa31.9 ksi

Hardness, Rockwell B

77 HRB
90 HRB

Hardness, Vickers

148 HV
192 HV

Same in both: Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 135 GPa19.6 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,020°C1,868 °F · Liquidus Temperature 1,055°C1,931 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

182 W/m·K105 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

160°C320 °F
130°C266 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
43 % IACS

Electrical Resistivity

3.83×10⁻⁸ Ω·m1.51 µΩ·in
4.01×10⁻⁸ Ω·m1.58 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

21 / 100
25 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Weldability

45 / 100
35 / 100

Formability (cold)

60 / 100
25 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19800

C19800-H02 vs C19800-H08 — frequently asked

Is C19800-H08 stronger than C19800-H02?

Yes. C19800-H08 has a typical yield strength of 595 MPa (86.3 ksi) against 415 MPa (60.2 ksi) for C19800-H02 — about 43% more. Tensile strength is 615 MPa (89.2 ksi) vs 455 MPa (66 ksi).

Which condition does FabDigit quote by default, H02 or H08?

H04 is the default C19800 condition in the FabDigit quote flow (neither H02 nor H08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C19800-H02 or C19800-H08?

C19800-H02. Its weldability rates fair (45/100) against fair (35/100) for C19800-H08.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19800-H02 and C19800-H08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.