Copper Alloy C19800-H02 vs C19800-H04

Copper Alloy · C19800 temper comparison

C19800-H02 and C19800-H04 are two conditions of the same copper alloy grade, C19800: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C19800-H04 is the stronger of the two: yield strength 495 MPa (71.8 ksi) against 415 MPa (60.2 ksi) for C19800-H02, about 19% more; tensile strength follows at 520 MPa (75.4 ksi) vs 455 MPa (66 ksi). In exchange, C19800-H02 is the more ductile: elongation 8% versus 4% for C19800-H04, and C19800-H04 is harder (165 HV vs 148 HV).

C19800-H02Choose it when the part is bent, formed or impact-loaded.

C19800-H04Choose it when strength drives the design.

C19800-H02 vs C19800-H04: properties

C19800-H02C19800-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

455 MPa66 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
495 MPa71.8 ksi

Elongation at Break

8%
4%

Shear Strength

295 MPa42.8 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
200 MPa29 ksi

Hardness, Rockwell B

77 HRB
82 HRB

Hardness, Vickers

148 HV
165 HV

Same in both: Elastic (Young's) Modulus 120 GPa17.4 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 135 GPa19.6 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,020°C1,868 °F · Liquidus Temperature 1,055°C1,931 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

182 W/m·K105 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Max Service Temperature (continuous)

160°C320 °F
150°C302 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 45 % IACS · Electrical Resistivity 3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

21 / 100
22 / 100

Formability (cold)

60 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 45 / 100 · Brazeability / Solderability 85 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19800

C19800-H02 vs C19800-H04 — frequently asked

Is C19800-H04 stronger than C19800-H02?

Yes. C19800-H04 has a typical yield strength of 495 MPa (71.8 ksi) against 415 MPa (60.2 ksi) for C19800-H02 — about 19% more. Tensile strength is 520 MPa (75.4 ksi) vs 455 MPa (66 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H04 is the default C19800 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C19800-H02 over C19800-H04?

Pick C19800-H02 when the part is bent, formed or impact-loaded. Pick C19800-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19800-H02 and C19800-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.