Copper Alloy C19500-H04 vs C19500-TF00
Copper Alloy · C19500 temper comparison
C19500-H04 and C19500-TF00 are two conditions of the same copper alloy grade, C19500: H04 (full hard) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C19500-H04 is the stronger of the two: yield strength 586 MPa (85 ksi) against 470 MPa (68.2 ksi) for C19500-TF00, about 25% more; tensile strength follows at 621 MPa (90.1 ksi) vs 540 MPa (78.3 ksi). In exchange, C19500-TF00 is the more ductile: elongation 10% versus 3% for C19500-H04, and C19500-H04 is harder (195 HV vs 160 HV). C19500-TF00 runs hotter in service (250°C vs 180°C continuous).
C19500-H04Choose it when strength drives the design.
C19500-TF00Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.
C19500-H04 vs C19500-TF00: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Rockwell B
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 131 GPa19 Msi · Shear Modulus 48 GPa7 Msi · Bulk Modulus 135 GPa19.6 Msi · Poisson's Ratio 0.33
Physical
Density and transition temperatures.
Same in both: Density 8.78 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,075°C1,967 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Same in both: Electrical Resistivity 3.45×10⁻⁸ Ω·m1.36 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 62 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Formability (cold)
Same in both: Machinability Rating (AISI 1212 = 100 %) 45% · Weldability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 40%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C19500-H04 vs C19500-TF00 — frequently asked
Is C19500-H04 stronger than C19500-TF00?
Yes. C19500-H04 has a typical yield strength of 586 MPa (85 ksi) against 470 MPa (68.2 ksi) for C19500-TF00 — about 25% more. Tensile strength is 621 MPa (90.1 ksi) vs 540 MPa (78.3 ksi).
Which condition does FabDigit quote by default, H04 or TF00?
H02 is the default C19500 condition in the FabDigit quote flow (neither H04 nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
When should I choose C19500-H04 over C19500-TF00?
Pick C19500-H04 when strength drives the design. Pick C19500-TF00 when the part is bent, formed or impact-loaded, or when the part sees heat.
Ready to make it?
Upload a CAD file and FabDigit prices the part in C19500-H04 and C19500-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
