FabDigitFabDigit

Copper Alloy C19500-H04 vs C19500-O60

Copper Alloy · C19500 temper comparison

C19500-H04 and C19500-O60 are two conditions of the same copper alloy grade, C19500: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C19500-H04 is the stronger of the two: yield strength 586 MPa (85 ksi) against 170 MPa (24.7 ksi) for C19500-O60, about 3.4 times as much; tensile strength follows at 621 MPa (90.1 ksi) vs 400 MPa (58 ksi). In exchange, C19500-O60 is the more ductile: elongation 24% versus 3% for C19500-H04, and C19500-H04 is harder (195 HV vs 100 HV). C19500-O60 runs hotter in service (250°C vs 180°C continuous) and C19500-H04 conducts electricity better (50 % IACS vs 45 % IACS). On the shop floor, C19500-H04 machines more easily (34 vs 22 out of 100).

C19500-H04Choose it when strength drives the design, or when the part is machined in volume.

C19500-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19500-H04 vs C19500-O60: properties

C19500-H04C19500-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

621 MPa90.1 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

586 MPa85 ksi
170 MPa24.7 ksi

Elongation at Break

3%
24%

Shear Strength

380 MPa55.1 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

250 MPa36.3 ksi
150 MPa21.8 ksi

Hardness, Rockwell B

88 HRB
55 HRB

Hardness, Vickers

195 HV
100 HV

Same in both: Elastic (Young's) Modulus 131 GPa19 Msi · Shear Modulus 48 GPa7 Msi · Bulk Modulus 135 GPa19.6 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.78 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,075°C1,967 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
185 W/m·K107 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
45 % IACS

Same in both: Electrical Resistivity 3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
22 / 100

Formability (cold)

35 / 100
88 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 45% · Weldability 40 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19500

C19500-H04 vs C19500-O60 — frequently asked

Is C19500-H04 stronger than C19500-O60?

Yes. C19500-H04 has a typical yield strength of 586 MPa (85 ksi) against 170 MPa (24.7 ksi) for C19500-O60 — about 3.4 times as much. Tensile strength is 621 MPa (90.1 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H04 or O60?

H02 is the default C19500 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C19500-H04 or C19500-O60?

C19500-H04, by a small margin. Both rate poor for machinability — 34/100 against 22/100 for C19500-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19500-H04 and C19500-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.