FabDigitFabDigit

Copper Alloy C19210-H01 vs C19210-H03

Copper Alloy · C19210 temper comparison

C19210-H01 and C19210-H03 are two conditions of the same copper alloy grade, C19210: H01 (quarter hard) versus H03 (three-quarter hard). The chemistry is identical, so every difference below comes from the condition. C19210-H03 is the stronger of the two: yield strength 315 MPa (45.7 ksi) against 225 MPa (32.6 ksi) for C19210-H01, about 40% more; tensile strength follows at 345 MPa (50 ksi) vs 280 MPa (40.6 ksi). In exchange, C19210-H01 is the more ductile: elongation 15% versus 7% for C19210-H03, and C19210-H03 is harder (118 HV vs 95 HV). C19210-H01 runs hotter in service (230°C vs 200°C continuous).

C19210-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19210-H03Choose it when strength drives the design.

C19210-H01 vs C19210-H03: properties

C19210-H01C19210-H03

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

280 MPa40.6 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

225 MPa32.6 ksi
315 MPa45.7 ksi

Elongation at Break

15%
7%

Shear Strength

180 MPa26.1 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
130 MPa18.9 ksi

Hardness, Rockwell B

38 HRB
55 HRB

Hardness, Vickers

95 HV
118 HV

Same in both: Elastic (Young's) Modulus 121 GPa17.5 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,080°C1,976 °F · Liquidus Temperature 1,084°C1,983 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

364 W/m·K210 BTU/hr·ft·°F
360 W/m·K208 BTU/hr·ft·°F

Max Service Temperature (continuous)

230°C446 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

91 % IACS
90 % IACS

Electrical Resistivity

1.9×10⁻⁸ Ω·m0.746 µΩ·in
1.92×10⁻⁸ Ω·m0.754 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
26 / 100

Machinability Rating (AISI 1212 = 100 %)

19%
21%

Weldability

45 / 100
43 / 100

Formability (cold)

82 / 100
68 / 100

Same in both: Brazeability / Solderability 90 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19210

C19210-H01 vs C19210-H03 — frequently asked

Is C19210-H03 stronger than C19210-H01?

Yes. C19210-H03 has a typical yield strength of 315 MPa (45.7 ksi) against 225 MPa (32.6 ksi) for C19210-H01 — about 40% more. Tensile strength is 345 MPa (50 ksi) vs 280 MPa (40.6 ksi).

Which condition does FabDigit quote by default, H01 or H03?

H04 is the default C19210 condition in the FabDigit quote flow (neither H01 nor H03). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C19210-H01 over C19210-H03?

Pick C19210-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C19210-H03 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19210-H01 and C19210-H03 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.