FabDigitFabDigit

Copper Alloy C19000-HR01 vs C19000-TF00

Copper Alloy · C19000 temper comparison

C19000-HR01 and C19000-TF00 are two conditions of the same copper alloy grade, C19000: HR01 (quarter hard, cold rolled and stress relieved) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C19000-HR01 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 310 MPa (45 ksi) for C19000-TF00, about 23% more; tensile strength follows at 425 MPa (61.6 ksi) vs 400 MPa (58 ksi). In exchange, C19000-TF00 is the more ductile: elongation 18% versus 13% for C19000-HR01, and C19000-HR01 is harder (135 HV vs 125 HV). C19000-TF00 runs hotter in service (250°C vs 200°C continuous).

C19000-HR01Choose it when strength drives the design.

C19000-TF00Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19000-HR01 vs C19000-TF00: properties

C19000-HR01C19000-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

425 MPa61.6 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
310 MPa45 ksi

Elongation at Break

13%
18%

Shear Strength

262 MPa38 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

175 MPa25.4 ksi
160 MPa23.2 ksi

Hardness, Rockwell B

72 HRB
68 HRB

Hardness, Vickers

135 HV
125 HV

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,075°C1,967 °F · Liquidus Temperature 1,099°C2,010 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

185 W/m·K107 BTU/hr·ft·°F
195 W/m·K113 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

45 % IACS
48 % IACS

Electrical Resistivity

3.83×10⁻⁸ Ω·m1.51 µΩ·in
3.59×10⁻⁸ Ω·m1.41 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

70 / 100
60 / 100

Same in both: Machinability 25 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 55 / 100 · Castability 40 / 100 · Brazeability / Solderability 85 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19000

C19000-HR01 vs C19000-TF00 — frequently asked

Is C19000-HR01 stronger than C19000-TF00?

Yes. C19000-HR01 has a typical yield strength of 380 MPa (55.1 ksi) against 310 MPa (45 ksi) for C19000-TF00 — about 23% more. Tensile strength is 425 MPa (61.6 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, HR01 or TF00?

HR02 is the default C19000 condition in the FabDigit quote flow (neither HR01 nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C19000-HR01 over C19000-TF00?

Pick C19000-HR01 when strength drives the design. Pick C19000-TF00 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19000-HR01 and C19000-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.