FabDigitFabDigit

Copper Alloy C18200-H vs C18200-TD04

Copper Alloy · C18200 temper comparison

C18200-H and C18200-TD04 are two conditions of the same copper alloy grade, C18200: H (hardened) versus TD04 (solution heat treated and cold worked, full hard). The chemistry is identical, so every difference below comes from the condition. C18200-H is the stronger of the two: yield strength 430 MPa (62.4 ksi) against 360 MPa (52.2 ksi) for C18200-TD04, about 19% more; tensile strength follows at 500 MPa (72.5 ksi) vs 400 MPa (58 ksi). C18200-H is the more ductile: elongation 18% versus 12% for C18200-TD04, and C18200-H is harder (140 HB vs 120 HB). C18200-H runs hotter in service (400°C vs 200°C continuous) and C18200-H conducts heat better (324 W/m·K vs 200 W/m·K).

C18200-HChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C18200-H vs C18200-TD04: properties

C18200-HC18200-TD04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

500 MPa72.5 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

430 MPa62.4 ksi
360 MPa52.2 ksi

Elongation at Break

18%
12%

Shear Strength

310 MPa45 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
140 MPa20.3 ksi

Hardness, Brinell

140 HB
120 HB

Hardness, Rockwell B

77 HRB
68 HRB

Hardness, Vickers

145 HV
125 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 133 GPa19.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,070°C1,958 °F · Liquidus Temperature 1,080°C1,976 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

324 W/m·K187 BTU/hr·ft·°F
200 W/m·K116 BTU/hr·ft·°F

Max Service Temperature (continuous)

400°C752 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

82 % IACS
45 % IACS

Electrical Resistivity

2.1×10⁻⁸ Ω·m0.827 µΩ·in
3.8×10⁻⁸ Ω·m1.5 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

60%
55%

Formability (cold)

35 / 100
30 / 100

Same in both: Weldability 30 / 100 · Brazeability / Solderability 75 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC18200

C18200-H vs C18200-TD04 — frequently asked

Is C18200-H stronger than C18200-TD04?

Yes. C18200-H has a typical yield strength of 430 MPa (62.4 ksi) against 360 MPa (52.2 ksi) for C18200-TD04 — about 19% more. Tensile strength is 500 MPa (72.5 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H or TD04?

H is the default C18200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C18200-H over C18200-TD04?

Pick C18200-H when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C18200-H and C18200-TD04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.