C17465-TB00 and C17465-TH04 are two conditions of the same copper alloy grade, C17465: TB00 (solution heat treated) versus TH04 (TD04 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17465-TH04 is the stronger of the two: yield strength 690 MPa (100 ksi) against 160 MPa (23.2 ksi) for C17465-TB00, about 4.3 times as much; tensile strength follows at 760 MPa (110 ksi) vs 330 MPa (47.9 ksi). In exchange, C17465-TB00 is the more ductile: elongation 28% versus 9% for C17465-TH04, and C17465-TH04 is harder (225 HB vs 90 HB). C17465-TH04 runs hotter in service (300°C vs 200°C continuous) and C17465-TH04 conducts heat better (220 W/m·K vs 125 W/m·K). On the shop floor, C17465-TH04 machines more easily (good vs fair) and C17465-TB00 welds better (30 vs 20 out of 100).

C17465-TB00Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

C17465-TH04Choose it when strength drives the design, or when the part sees heat.

C17465-TB00 vs C17465-TH04: properties

C17465-TB00C17465-TH04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

160 MPa23.2 ksi
690 MPa100 ksi

Elongation at Break

28%
9%

Reduction in Area

65%
35%

Shear Strength

230 MPa33.4 ksi
500 MPa72.5 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
275 MPa39.9 ksi

Hardness, Brinell

90 HB
225 HB

Hardness, Rockwell B

52 HRB
100 HRB

Hardness, Rockwell C

22 HRC
28 HRC

Hardness, Vickers

95 HV
240 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3 · Compressive Strength 560 MPa81.2 ksi · Charpy V-Notch Impact (RT) 30 J22.1 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
220 W/m·K127 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
300°C572 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
52 % IACS

Electrical Resistivity

6.16×10⁻⁸ Ω·m2.43 µΩ·in
3.32×10⁻⁸ Ω·m1.31 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

40%
50%

Weldability

30 / 100
20 / 100

Formability (cold)

75 / 100
15 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 40 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 100 MJ/kg42,992 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17465

C17465-TB00 vs C17465-TH04 — frequently asked

Is C17465-TH04 stronger than C17465-TB00?

Yes. C17465-TH04 has a typical yield strength of 690 MPa (100 ksi) against 160 MPa (23.2 ksi) for C17465-TB00 — about 4.3 times as much. Tensile strength is 760 MPa (110 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, TB00 or TH04?

TF00 is the default C17465 condition in the FabDigit quote flow (neither TB00 nor TH04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C17465-TB00 or C17465-TH04?

C17465-TH04. Its machinability rates good (62/100) against fair (50/100) for C17465-TB00; for welding the order is C17465-TB00 first (poor, 30/100) then C17465-TH04 (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17465-TB00 and C17465-TH04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.