FabDigitFabDigit

Copper Alloy C17460-TB00 vs C17460-TM08

Copper Alloy · C17460 temper comparison

C17460-TB00 and C17460-TM08 are two conditions of the same copper alloy grade, C17460: TB00 (solution heat treated) versus TM08 (mill hardened, spring hard). The chemistry is identical, so every difference below comes from the condition. C17460-TM08 is the stronger of the two: yield strength 780 MPa (113 ksi) against 170 MPa (24.7 ksi) for C17460-TB00, about 4.6 times as much; tensile strength follows at 860 MPa (125 ksi) vs 340 MPa (49.3 ksi). In exchange, C17460-TB00 is the more ductile: elongation 28% versus 7% for C17460-TM08, and C17460-TM08 is harder (240 HB vs 95 HB). C17460-TM08 runs hotter in service (320°C vs 150°C continuous) and C17460-TM08 conducts heat better (220 W/m·K vs 130 W/m·K). On the shop floor, C17460-TM08 machines more easily (fair vs poor) and C17460-TB00 welds better (50 vs 40 out of 100).

C17460-TB00Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

C17460-TM08Choose it when strength drives the design, or when the part sees heat.

C17460-TB00 vs C17460-TM08: properties

C17460-TB00C17460-TM08

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

132 GPa19.1 Msi
138 GPa20 Msi

Tensile Strength (Ultimate)

340 MPa49.3 ksi
860 MPa125 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
780 MPa113 ksi

Elongation at Break

28%
7%

Shear Strength

215 MPa31.2 ksi
535 MPa77.6 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
275 MPa39.9 ksi

Hardness, Brinell

95 HB
240 HB

Hardness, Rockwell B

50 HRB
99 HRB

Hardness, Rockwell C

20 HRC
24 HRC

Hardness, Vickers

100 HV
255 HV

Same in both: Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
220 W/m·K127 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
320°C608 °F

Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
50 % IACS

Electrical Resistivity

6.16×10⁻⁸ Ω·m2.43 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
48 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
32%

Weldability

50 / 100
40 / 100

Formability (cold)

80 / 100
25 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17460

C17460-TB00 vs C17460-TM08 — frequently asked

Is C17460-TM08 stronger than C17460-TB00?

Yes. C17460-TM08 has a typical yield strength of 780 MPa (113 ksi) against 170 MPa (24.7 ksi) for C17460-TB00 — about 4.6 times as much. Tensile strength is 860 MPa (125 ksi) vs 340 MPa (49.3 ksi).

Which condition does FabDigit quote by default, TB00 or TM08?

TF00 is the default C17460 condition in the FabDigit quote flow (neither TB00 nor TM08). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C17460-TB00 or C17460-TM08?

C17460-TM08. Its machinability rates fair (48/100) against poor (30/100) for C17460-TB00; for welding the order is C17460-TB00 first (fair, 50/100) then C17460-TM08 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17460-TB00 and C17460-TM08 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.