Copper Alloy C17460-TB00 vs C17460-TM06
Copper Alloy · C17460 temper comparison
C17460-TB00 and C17460-TM06 are two conditions of the same copper alloy grade, C17460: TB00 (solution heat treated) versus TM06 (mill hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. C17460-TM06 is the stronger of the two: yield strength 710 MPa (103 ksi) against 170 MPa (24.7 ksi) for C17460-TB00, about 4.2 times as much; tensile strength follows at 800 MPa (116 ksi) vs 340 MPa (49.3 ksi). In exchange, C17460-TB00 is the more ductile: elongation 28% versus 9% for C17460-TM06, and C17460-TM06 is harder (225 HB vs 95 HB). C17460-TM06 runs hotter in service (330°C vs 150°C continuous) and C17460-TM06 conducts heat better (220 W/m·K vs 130 W/m·K). On the shop floor, C17460-TM06 machines more easily (fair vs poor).
C17460-TB00Choose it when the part is bent, formed or impact-loaded.
C17460-TM06Choose it when strength drives the design, or when the part sees heat.
C17460-TB00 vs C17460-TM06: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Rockwell B
Hardness, Rockwell C
Hardness, Vickers
Same in both: Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3
Physical
Density and transition temperatures.
Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,070°C1,958 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.5 µm/m·K9.7 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 65 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C17460-TB00 vs C17460-TM06 — frequently asked
Is C17460-TM06 stronger than C17460-TB00?
Yes. C17460-TM06 has a typical yield strength of 710 MPa (103 ksi) against 170 MPa (24.7 ksi) for C17460-TB00 — about 4.2 times as much. Tensile strength is 800 MPa (116 ksi) vs 340 MPa (49.3 ksi).
Which condition does FabDigit quote by default, TB00 or TM06?
TF00 is the default C17460 condition in the FabDigit quote flow (neither TB00 nor TM06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, C17460-TB00 or C17460-TM06?
C17460-TM06. Its machinability rates fair (45/100) against poor (30/100) for C17460-TB00; for welding the order is C17460-TB00 first (fair, 50/100) then C17460-TM06 (fair, 43/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in C17460-TB00 and C17460-TM06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
