FabDigitFabDigit

Copper Alloy C17410-TH04 vs C17410-TM00

Copper Alloy · C17410 temper comparison

C17410-TH04 and C17410-TM00 are two conditions of the same copper alloy grade, C17410: TH04 (TD04 and precipitation hardened) versus TM00 (mill hardened). The chemistry is identical, so every difference below comes from the condition. C17410-TH04 is the stronger of the two: yield strength 725 MPa (105 ksi) against 520 MPa (75.4 ksi) for C17410-TM00, about 39% more; tensile strength follows at 795 MPa (115 ksi) vs 620 MPa (89.9 ksi). In exchange, C17410-TM00 is the more ductile: elongation 16% versus 7% for C17410-TH04, and C17410-TH04 is harder (235 HV vs 180 HV).

C17410-TH04Choose it when strength drives the design.

C17410-TM00Choose it when the part is bent, formed or impact-loaded.

C17410-TH04 vs C17410-TM00: properties

C17410-TH04C17410-TM00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

138 GPa20 Msi
135 GPa19.6 Msi

Tensile Strength (Ultimate)

795 MPa115 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

725 MPa105 ksi
520 MPa75.4 ksi

Elongation at Break

7%
16%

Shear Strength

505 MPa73.2 ksi
415 MPa60.2 ksi

Fatigue Strength (Endurance Limit)

290 MPa42.1 ksi
240 MPa34.8 ksi

Hardness, Rockwell B

98 HRB
88 HRB

Hardness, Vickers

235 HV
180 HV

Same in both: Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

205 W/m·K118 BTU/hr·ft·°F
225 W/m·K130 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

47 % IACS
52 % IACS

Electrical Resistivity

3.67×10⁻⁸ Ω·m1.44 µΩ·in
3.32×10⁻⁸ Ω·m1.31 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

52 / 100
55 / 100

Formability (cold)

30 / 100
65 / 100

Same in both: Machinability 45 / 100 · Machinability Rating (AISI 1212 = 100 %) 35% · Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17410

C17410-TH04 vs C17410-TM00 — frequently asked

Is C17410-TH04 stronger than C17410-TM00?

Yes. C17410-TH04 has a typical yield strength of 725 MPa (105 ksi) against 520 MPa (75.4 ksi) for C17410-TM00 — about 39% more. Tensile strength is 795 MPa (115 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, TH04 or TM00?

TM04 is the default C17410 condition in the FabDigit quote flow (neither TH04 nor TM00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C17410-TH04 over C17410-TM00?

Pick C17410-TH04 when strength drives the design. Pick C17410-TM00 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17410-TH04 and C17410-TM00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.