FabDigitFabDigit

Copper Alloy C17410-TH01 vs C17410-TM06

Copper Alloy · C17410 temper comparison

C17410-TH01 and C17410-TM06 are two conditions of the same copper alloy grade, C17410: TH01 (TD01 and precipitation hardened) versus TM06 (mill hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. C17410-TM06 is the stronger of the two: yield strength 760 MPa (110 ksi) against 620 MPa (89.9 ksi) for C17410-TH01, about 23% more; tensile strength follows at 795 MPa (115 ksi) vs 690 MPa (100 ksi). In exchange, C17410-TH01 is the more ductile: elongation 12% versus 8% for C17410-TM06, and C17410-TM06 is harder (228 HV vs 198 HV). C17410-TH01 conducts electricity better (50 % IACS vs 45 % IACS).

C17410-TH01Choose it when the part is bent, formed or impact-loaded.

C17410-TM06Choose it when strength drives the design.

C17410-TH01 vs C17410-TM06: properties

C17410-TH01C17410-TM06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
795 MPa115 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
760 MPa110 ksi

Elongation at Break

12%
8%

Shear Strength

450 MPa65.3 ksi
505 MPa73.2 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
295 MPa42.8 ksi

Hardness, Rockwell B

92 HRB
97 HRB

Hardness, Vickers

198 HV
228 HV

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

215 W/m·K124 BTU/hr·ft·°F
200 W/m·K116 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
45 % IACS

Electrical Resistivity

3.45×10⁻⁸ Ω·m1.36 µΩ·in
3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

55 / 100
52 / 100

Formability (cold)

50 / 100
35 / 100

Same in both: Machinability 45 / 100 · Machinability Rating (AISI 1212 = 100 %) 35% · Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 72 MJ/kg30,954 BTU/lb · Embodied Carbon (primary production) 5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17410

C17410-TH01 vs C17410-TM06 — frequently asked

Is C17410-TM06 stronger than C17410-TH01?

Yes. C17410-TM06 has a typical yield strength of 760 MPa (110 ksi) against 620 MPa (89.9 ksi) for C17410-TH01 — about 23% more. Tensile strength is 795 MPa (115 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, TH01 or TM06?

TM04 is the default C17410 condition in the FabDigit quote flow (neither TH01 nor TM06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C17410-TH01 over C17410-TM06?

Pick C17410-TH01 when the part is bent, formed or impact-loaded. Pick C17410-TM06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17410-TH01 and C17410-TM06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.