FabDigitFabDigit

Copper Alloy C16200-H01 vs C16200-H10

Copper Alloy · C16200 temper comparison

C16200-H01 and C16200-H10 are two conditions of the same copper alloy grade, C16200: H01 (quarter hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C16200-H10 is the stronger of the two: yield strength 510 MPa (74 ksi) against 230 MPa (33.4 ksi) for C16200-H01, about 122% more; tensile strength follows at 540 MPa (78.3 ksi) vs 315 MPa (45.7 ksi). In exchange, C16200-H01 is the more ductile: elongation 25% versus 2% for C16200-H10, and C16200-H10 is harder (145 HB vs 80 HB). C16200-H01 runs hotter in service (200°C vs 175°C continuous). On the shop floor, C16200-H10 machines more easily (30 vs 20 out of 100) and C16200-H01 welds better (fair vs poor).

C16200-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C16200-H10Choose it when strength drives the design, or when the part is machined in volume.

C16200-H01 vs C16200-H10: properties

C16200-H01C16200-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

315 MPa45.7 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

230 MPa33.4 ksi
510 MPa74 ksi

Elongation at Break

25%
2%

Shear Strength

215 MPa31.2 ksi
320 MPa46.4 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
195 MPa28.3 ksi

Hardness, Brinell

80 HB
145 HB

Hardness, Rockwell B

42 HRB
82 HRB

Hardness, Vickers

85 HV
152 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,076°C1,969 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

358 W/m·K207 BTU/hr·ft·°F
338 W/m·K195 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

89 % IACS
84 % IACS

Electrical Resistivity

1.94×10⁻⁸ Ω·m0.764 µΩ·in
2.05×10⁻⁸ Ω·m0.807 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
25%

Weldability

40 / 100
30 / 100

Formability (cold)

65 / 100
10 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC16200

C16200-H01 vs C16200-H10 — frequently asked

Is C16200-H10 stronger than C16200-H01?

Yes. C16200-H10 has a typical yield strength of 510 MPa (74 ksi) against 230 MPa (33.4 ksi) for C16200-H01 — about 122% more. Tensile strength is 540 MPa (78.3 ksi) vs 315 MPa (45.7 ksi).

Which condition does FabDigit quote by default, H01 or H10?

H04 is the default C16200 condition in the FabDigit quote flow (neither H01 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C16200-H01 or C16200-H10?

C16200-H10, by a small margin. Both rate poor for machinability — 30/100 against 20/100 for C16200-H01; for welding the order is C16200-H01 first (fair, 40/100) then C16200-H10 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C16200-H01 and C16200-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.