FabDigitFabDigit

Copper Alloy C15100-H04 vs C15100-H06

Copper Alloy · C15100 temper comparison

C15100-H04 and C15100-H06 are two conditions of the same copper alloy grade, C15100: H04 (full hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C15100-H06 is the stronger of the two: yield strength 375 MPa (54.4 ksi) against 330 MPa (47.9 ksi) for C15100-H04, about 14% more; tensile strength follows at 400 MPa (58 ksi) vs 360 MPa (52.2 ksi). In exchange, C15100-H04 is the more ductile: elongation 6% versus 4% for C15100-H06, and C15100-H06 is harder (118 HB vs 105 HB).

C15100-H04Choose it when the part is bent, formed or impact-loaded.

C15100-H06Choose it when strength drives the design.

C15100-H04 vs C15100-H06: properties

C15100-H04C15100-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

360 MPa52.2 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
375 MPa54.4 ksi

Elongation at Break

6%
4%

Shear Strength

215 MPa31.2 ksi
235 MPa34.1 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
160 MPa23.2 ksi

Hardness, Brinell

105 HB
118 HB

Hardness, Rockwell B

62 HRB
70 HRB

Hardness, Vickers

115 HV
130 HV

Same in both: Elastic (Young's) Modulus 120 GPa17.4 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,080°C1,976 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

350 W/m·K202 BTU/hr·ft·°F
347 W/m·K200 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 450°C842 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

92 % IACS
91 % IACS

Electrical Resistivity

1.87×10⁻⁸ Ω·m0.736 µΩ·in
1.89×10⁻⁸ Ω·m0.744 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
24 / 100

Formability (cold)

40 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 45 / 100 · Castability 45 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC15100

C15100-H04 vs C15100-H06 — frequently asked

Is C15100-H06 stronger than C15100-H04?

Yes. C15100-H06 has a typical yield strength of 375 MPa (54.4 ksi) against 330 MPa (47.9 ksi) for C15100-H04 — about 14% more. Tensile strength is 400 MPa (58 ksi) vs 360 MPa (52.2 ksi).

Which condition does FabDigit quote by default, H04 or H06?

H04 is the default C15100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C15100-H04 over C15100-H06?

Pick C15100-H04 when the part is bent, formed or impact-loaded. Pick C15100-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C15100-H04 and C15100-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.