C15100-H02 and C15100-H04 are two conditions of the same copper alloy grade, C15100: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C15100-H04 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 270 MPa (39.2 ksi) for C15100-H02, about 22% more; tensile strength follows at 360 MPa (52.2 ksi) vs 310 MPa (45 ksi). In exchange, C15100-H02 is the more ductile: elongation 14% versus 6% for C15100-H04, and C15100-H04 is harder (105 HB vs 88 HB).

C15100-H02Choose it when the part is bent, formed or impact-loaded.

C15100-H04Choose it when strength drives the design.

C15100-H02 vs C15100-H04: properties

C15100-H02C15100-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
360 MPa52.2 ksi

Yield Strength (0.2% offset)

270 MPa39.2 ksi
330 MPa47.9 ksi

Elongation at Break

14%
6%

Shear Strength

195 MPa28.3 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
150 MPa21.8 ksi

Hardness, Brinell

88 HB
105 HB

Hardness, Rockwell B

50 HRB
62 HRB

Hardness, Vickers

96 HV
115 HV

Same in both: Elastic (Young's) Modulus 120 GPa17.4 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,080°C1,976 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

358 W/m·K207 BTU/hr·ft·°F
350 W/m·K202 BTU/hr·ft·°F

Max Service Temperature (continuous)

430°C806 °F
450°C842 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

93 % IACS
92 % IACS

Electrical Resistivity

1.85×10⁻⁸ Ω·m0.728 µΩ·in
1.87×10⁻⁸ Ω·m0.736 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

21 / 100
22 / 100

Formability (cold)

60 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 45 / 100 · Castability 45 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC15100

C15100-H02 vs C15100-H04 — frequently asked

Is C15100-H04 stronger than C15100-H02?

Yes. C15100-H04 has a typical yield strength of 330 MPa (47.9 ksi) against 270 MPa (39.2 ksi) for C15100-H02 — about 22% more. Tensile strength is 360 MPa (52.2 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H04 is the default C15100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C15100-H02 over C15100-H04?

Pick C15100-H02 when the part is bent, formed or impact-loaded. Pick C15100-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C15100-H02 and C15100-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.