FabDigitFabDigit

Copper Alloy C14500-H02 vs C14500-H80

Copper Alloy · C14500 temper comparison

C14500-H02 and C14500-H80 are two conditions of the same copper alloy grade, C14500: H02 (half hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C14500-H02 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 90 MPa (13.1 ksi) for C14500-H80, about 3.1 times as much; tensile strength follows at 310 MPa (45 ksi) vs 240 MPa (34.8 ksi). In exchange, C14500-H80 is the more ductile: elongation 40% versus 18% for C14500-H02, and C14500-H02 is harder (85 HB vs 50 HB). C14500-H80 runs hotter in service (300°C vs 200°C continuous).

C14500-H02Choose it when strength drives the design.

C14500-H80Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C14500-H02 vs C14500-H80: properties

C14500-H02C14500-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
90 MPa13.1 ksi

Elongation at Break

18%
40%

Shear Strength

195 MPa28.3 ksi
160 MPa23.2 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
75 MPa10.9 ksi

Hardness, Brinell

85 HB
50 HB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Hardness, Rockwell B 40 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,051°C1,924 °F · Liquidus Temperature 1,065°C1,949 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

350 W/m·K202 BTU/hr·ft·°F
355 W/m·K205 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
300°C572 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

92 % IACS
94 % IACS

Electrical Resistivity

1.87×10⁻⁸ Ω·m0.736 µΩ·in
1.83×10⁻⁸ Ω·m0.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
80 / 100

Formability (cold)

40 / 100
60 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 90 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC14500

C14500-H02 vs C14500-H80 — frequently asked

Is C14500-H02 stronger than C14500-H80?

Yes. C14500-H02 has a typical yield strength of 275 MPa (39.9 ksi) against 90 MPa (13.1 ksi) for C14500-H80 — about 3.1 times as much. Tensile strength is 310 MPa (45 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, H02 or H80?

H02 is the default C14500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C14500-H02 or C14500-H80?

C14500-H02. Its machinability rates excellent (85/100) against very good (80/100) for C14500-H80.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C14500-H02 and C14500-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.