FabDigitFabDigit

Copper Alloy C14500-H02 vs C14500-H04

Copper Alloy · C14500 temper comparison

C14500-H02 and C14500-H04 are two conditions of the same copper alloy grade, C14500: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C14500-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 275 MPa (39.9 ksi) for C14500-H02, about 13% more; tensile strength follows at 345 MPa (50 ksi) vs 310 MPa (45 ksi). In exchange, C14500-H02 is the more ductile: elongation 18% versus 12% for C14500-H04, and C14500-H04 is harder (100 HB vs 85 HB). C14500-H02 runs hotter in service (200°C vs 180°C continuous).

C14500-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C14500-H04Choose it when strength drives the design.

C14500-H02 vs C14500-H04: properties

C14500-H02C14500-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
310 MPa45 ksi

Elongation at Break

18%
12%

Shear Strength

195 MPa28.3 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
110 MPa16 ksi

Hardness, Brinell

85 HB
100 HB

Hardness, Rockwell B

40 HRB
50 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,051°C1,924 °F · Liquidus Temperature 1,065°C1,949 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

350 W/m·K202 BTU/hr·ft·°F
345 W/m·K199 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
180°C356 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

92 % IACS
90 % IACS

Electrical Resistivity

1.87×10⁻⁸ Ω·m0.736 µΩ·in
1.92×10⁻⁸ Ω·m0.756 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
88 / 100

Formability (cold)

40 / 100
25 / 100

Same in both: Weldability 25 / 100 · Brazeability / Solderability 90 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC14500

C14500-H02 vs C14500-H04 — frequently asked

Is C14500-H04 stronger than C14500-H02?

Yes. C14500-H04 has a typical yield strength of 310 MPa (45 ksi) against 275 MPa (39.9 ksi) for C14500-H02 — about 13% more. Tensile strength is 345 MPa (50 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C14500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C14500-H02 over C14500-H04?

Pick C14500-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C14500-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C14500-H02 and C14500-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.