FabDigitFabDigit

Copper Alloy C14200-H01 vs C14200-H80

Copper Alloy · C14200 temper comparison

C14200-H01 and C14200-H80 are two conditions of the same copper alloy grade, C14200: H01 (quarter hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C14200-H80 is the stronger of the two: yield strength 345 MPa (50 ksi) against 200 MPa (29 ksi) for C14200-H01, about 73% more; tensile strength follows at 380 MPa (55.1 ksi) vs 260 MPa (37.7 ksi). In exchange, C14200-H01 is the more ductile: elongation 25% versus 8% for C14200-H80, and C14200-H80 is harder (100 HB vs 70 HB). C14200-H01 runs hotter in service (300°C vs 200°C continuous).

C14200-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C14200-H80Choose it when strength drives the design.

C14200-H01 vs C14200-H80: properties

C14200-H01C14200-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

200 MPa29 ksi
345 MPa50 ksi

Elongation at Break

25%
8%

Shear Strength

175 MPa25.4 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
110 MPa16 ksi

Hardness, Brinell

70 HB
100 HB

Hardness, Vickers

73 HV
110 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

300°C572 °F
200°C392 °F

Same in both: Thermal Conductivity 190 W/m·K110 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Same in both: Electrical Resistivity 4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Formability (cold)

80 / 100
45 / 100

Same in both: Weldability 70 / 100 · Brazeability / Solderability 95 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC14200

C14200-H01 vs C14200-H80 — frequently asked

Is C14200-H80 stronger than C14200-H01?

Yes. C14200-H80 has a typical yield strength of 345 MPa (50 ksi) against 200 MPa (29 ksi) for C14200-H01 — about 73% more. Tensile strength is 380 MPa (55.1 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, H01 or H80?

OS050 is the default C14200 condition in the FabDigit quote flow (neither H01 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C14200-H01 or C14200-H80?

C14200-H01. Its machinability rates fair (35/100) against poor (30/100) for C14200-H80.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C14200-H01 and C14200-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.