FabDigitFabDigit

Copper Alloy C12500-H01 vs C12500-H03

Copper Alloy · C12500 temper comparison

C12500-H01 and C12500-H03 are two conditions of the same copper alloy grade, C12500: H01 (quarter hard) versus H03 (three-quarter hard). The chemistry is identical, so every difference below comes from the condition. C12500-H03 is the stronger of the two: yield strength 275 MPa (39.9 ksi) against 205 MPa (29.7 ksi) for C12500-H01, about 34% more; tensile strength follows at 315 MPa (45.7 ksi) vs 265 MPa (38.4 ksi). In exchange, C12500-H01 is the more ductile: elongation 25% versus 10% for C12500-H03, and C12500-H03 is harder (89 HB vs 70 HB). C12500-H01 runs hotter in service (175°C vs 150°C continuous).

C12500-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C12500-H03Choose it when strength drives the design.

C12500-H01 vs C12500-H03: properties

C12500-H01C12500-H03

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

265 MPa38.4 ksi
315 MPa45.7 ksi

Yield Strength (0.2% offset)

205 MPa29.7 ksi
275 MPa39.9 ksi

Elongation at Break

25%
10%

Shear Strength

175 MPa25.4 ksi
198 MPa28.7 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
110 MPa16 ksi

Hardness, Brinell

70 HB
89 HB

Hardness, Rockwell B

25 HRB
44 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

386 W/m·K223 BTU/hr·ft·°F
385 W/m·K222 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

98 % IACS
97 % IACS

Electrical Resistivity

1.76×10⁻⁸ Ω·m0.693 µΩ·in
1.78×10⁻⁸ Ω·m0.701 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

21 / 100
22 / 100

Formability (cold)

70 / 100
42 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 35 / 100 · Castability 45 / 100 · Brazeability / Solderability 92 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 53 MJ/kg22,786 BTU/lb · Embodied Carbon (primary production) 3.3 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC12500

C12500-H01 vs C12500-H03 — frequently asked

Is C12500-H03 stronger than C12500-H01?

Yes. C12500-H03 has a typical yield strength of 275 MPa (39.9 ksi) against 205 MPa (29.7 ksi) for C12500-H01 — about 34% more. Tensile strength is 315 MPa (45.7 ksi) vs 265 MPa (38.4 ksi).

Which condition does FabDigit quote by default, H01 or H03?

H04 is the default C12500 condition in the FabDigit quote flow (neither H01 nor H03). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C12500-H01 over C12500-H03?

Pick C12500-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C12500-H03 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C12500-H01 and C12500-H03 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.